SUN2000-(50KTL-JPM0, 50KTL-JPM1, 63KTL-JPM0) User Manual

M:SUN2000-50KTL-JPM0,SUN2000-50KTL-JPM1,SUN2000-63KTL-JPM0;Smart PV inverter, Smart PV Controller, Cascading

M:SUN2000-50KTL-JPM0,SUN2000-50KTL-JPM1,SUN2000-63KTL-JPM0;Smart PV inverter, Smart PV Controller, Cascading

Technical Specifications

Technical Specifications

Efficiency

Item

SUN2000-50KTL-JPM0

SUN2000-50KTL-JPM1

SUN2000-63KTL-JPM0

Maximum efficiency

98.90% (@480 V)

98.70% (@440 V)

98.60% (@420 V)

98.90% (@480 V)

98.70% (@440 V)

98.90% (@480 V)

98.70% (@440 V)

Input

Item

SUN2000-50KTL-JPM0

SUN2000-50KTL-JPM1

SUN2000-63KTL-JPM0

Maximum input voltagea

1100 V

Operating voltage rangeb

200–1000 V

Maximum input current (per MPPT)

22 A

Maximum short-circuit current (per MPPT)

30 A

Maximum SUN2000 backfeed current to the PV array

0 A

Minimum startup voltage

200 V

Full power MPPT voltage rangec

600–850 V

Rated input voltage

640 V (@420 V), 670 V (@440 V), 720 V (@480 V)

670 V (@440 V), 720 V (@480 V)

670 V (@440 V), 720 V (@480 V)

Number of inputs

12

Number of MPP trackers

6

Note a: The maximum input voltage is the upper threshold of the DC voltage. If the input voltage exceeds the threshold, the solar inverter may be damaged.

Note b: If the input voltage is beyond the operating voltage range, the solar inverter cannot work properly.

Note c: PV strings connecting to the same MPPT must contain the same quantity and model of PV modules. It is recommended that the PV string voltage be higher than the lower threshold of the full-load MPPT voltage.

Output

Item

SUN2000-50KTL-JPM0

SUN2000-50KTL-JPM1

SUN2000-63KTL-JPM0

Rated active power

50 kW

49.9 kW

62.5 kW

Maximum apparent power

55.5 kVA

55.5 kVA

70 kVA

Maximum active power (cos = 1)

50 kW

49.9 kW

62.5 kW

Rated output voltagea

242.5 V/420 V, 254 V/440 V, 277 V/480 V, 3W+PE

254 V/440 V, 277 V/480 V, 3W+PE

254 V/440 V, 277 V/480 V, 3W+PE

Rated output current

68.8 A (@420 V), 65.7 A (@440 V), 60.2 A (@480 V)

65.5 A (@440 V), 60.1 A (@480 V)

82.1 A (@440 V), 75.2 A (@480 V)

Adapted grid frequency

50 Hz/60 Hz

Maximum output current

76.3 A (@420 V), 72.9 A (@440 V), 66.8 A (@480 V)

72.9 A (@440 V), 66.8 A (@480 V)

91.9 A (@440 V), 84.2 A (@480 V)

Power factor

0.8 leading... 0.8 lagging

Maximum total harmonic distortion (rated power)

< 3%

Note a: The rated output voltage is determined by Grid code, which can be set on the SUN2000 app, SmartLogger, or NetEco.

Protection

Item

SUN2000-50KTL-JPM0

SUN2000-50KTL-JPM1

SUN2000-63KTL-JPM0

Input DC switch

Supported

Anti-islanding protection

Supported

Output overcurrent protection

Supported

Input reverse polarity protection

Supported

PV string fault detection

Supported

DC surge protection

Type II

AC surge protection

Type II

Insulation resistance detection

Supported

Residual current monitoring unit (RCMU)

Supported

Overvoltage category

PV II/AC III

Built-in PID repaira

Optional

Not supported

Optional

Note a: When the SUN2000 is disconnected from the grid and stops working, the built-in PID can achieve the PV– positive offset of the PV module. (PV– positive offset refers to raising the voltage between PV– and the ground to above 0 V through voltage compensation.) When designing a power plant, confirm with the PV module manufacturer that the anti-PID voltage compensation direction of the PV module is the same as the direction of the PV– positive offset. Otherwise, PV modules may be damaged.

For the SUN2000 that supports built-in PID repair, when Built-in PID running mode is set to Repair, there is repair voltage between PV modules and the ground at night. If you need to maintain PV modules at night, power off the SUN2000 to avoid electric shocks.

Display and Communication

Item

SUN2000-50KTL-JPM0

SUN2000-50KTL-JPM1

SUN2000-63KTL-JPM0

Display

LED indicator, Bluetooth module+app, USB data cable+app, and WLAN module+app

Communication networking mode

RS485

Common Parameters

Item

SUN2000-50KTL-JPM0

SUN2000-50KTL-JPM1

SUN2000-63KTL-JPM0

Dimensions (W x H x D)

1075 mm x 555 mm x 300 mm

Net weight

About 71 kg

Operating temperature

-25°C to +60°C

Cooling mode

Natural convection

Highest operating altitude

4000 m

Humidity

0%–100% RH

Input terminal

Amphenol Helios H4

Output terminal

Cable gland+OT terminal

Ingress Protection Rating

IP65

Topology

Transformerless

Translation
Favorite
Download
Update Date:2025-08-13
Document ID:EDOC1100046285
Views:39640
Downloads:1413
Average rating:1.0Points

Digital Signature File

digtal sigature tool