HUAWEI Box 500, Box 700, Box 900 20.0.0 Configuration Guide
Describes the configuration process of products and their features, including initial configuration and adjusting configuration due to network or service changes.
Describes the configuration process of products and their features, including initial configuration and adjusting configuration due to network or service changes.
Interconnecting with the TR-069 Server
Context
The endpoint supports the CPE WAN Management Protocol (CWMP), a standard device management protocol numbered TR-069. Through this protocol, you can use the Auto-Configuration Server (ACS) to remotely manage customer-premises equipment (CPE) (that is, endpoints in the videoconferencing system), including querying and setting device parameters, uploading and downloading configuration files, reporting alarms, upgrading devices, restarting devices, managing public and private networks, collecting the endpoint logs, and uploading call history record (CHR) files.
Procedure
- Log in to the web interface, choose System Settings > Registration > TR069, and set the TR-069 parameters, as shown in Figure 6-5.
Table 6-3 TR-069 parameters
Parameter
Description
How to Set
TR069
Specifies whether to enable the TR-069 function. If this function is enabled, the endpoint will send a session setup request to the ACS. Start the ACS before enabling the TR-069 function.
NOTE:If you set this parameter to Enable, you must also set ACS user name, ACS password, ACS server IP address, Report interval (s), CPE user name, CPE password, and Authentication mode.
The default value is Disable.
ACS user name
Specifies the user name authenticated by the ACS after receiving a session setup request from the endpoint. The user name has been specified on the ACS.
The default value is eSight.
ACS password
Specifies the password authenticated by the ACS after receiving a session setup request from the endpoint The password has been specified on the ACS.
The default value is eSight*123.
ACS server IP address
Specifies the ACS URL, which can be based on an IP address or domain name.If an IP address is used, the value must be in the format of https://eSight IP address:8444/tr069/services/acs.
If a domain name is used, the value must be in the format of https://eSight domain name:8444/tr069/services/acs.
No default value is set for this parameter.
Report interval (s)
Specifies the interval at which the endpoint sends a session setup request to the ACS.
It is recommended that this interval be shorter than the timeout period of the ACS. If this interval is longer than the timeout period, the ACS may be disconnected or the session status may not be updated in time after a session setup timeout.
The default value is 1800.
CPE user name
Specifies the user name authenticated by the endpoint after receiving a session setup request from the ACS. The user name has been specified on the ACS.
The default value is admin.
CPE password
Specifies the password authenticated by the endpoint after receiving a session setup request from the ACS. The password has been specified on the ACS.
The default value is Change_Me.
Authentication mode
Specifies the mode in which the endpoint will be authenticated when connecting to the network management system.
The default value is recommended.
The default value is Digest.
STUN
Specifies whether to enable the Simple Traversal of UDP through NAT (STUN) function. If this function is enabled, the endpoint can perform private and public network traversal using the STUN server on the TR-069 network.
NOTE:If you set this parameter to Enable, you must also set STUN server IP address, STUN server port, STUN listen port, STUN user name, STUN password, and STUN keepalive period (s).
The default value is Disable.
STUN server IP address
Specifies the IP address of the STUN server.
Obtain it from the STUN server administrator.
No default value is set for this parameter.
STUN server port
Specifies the port number used by the STUN server to provide the private and public network traversal service.
Obtain it from the STUN server administrator.
The default value is 3478.
STUN listen port
Specifies the port provided by the endpoint for private and public service interaction with the STUN server.
The default value is 3000.
STUN user name
STUN password
Specifies the user name and password used to authenticate the STUN server.
Obtain them from the STUN server administrator.
NOTE:It is recommended that the password contain at least 16 characters that consist of letters, digits, and special characters.
No default value is set for this parameter.
STUN keepalive period (s)
Specifies the interval at which the endpoint sends a session setup request to the STUN server.
The default value is 150.
Log collection
Specifies whether eSight is allowed to collect the endpoint's logs.
The default value is Enable.
CHR switch
Specifies whether to enable the CHR collection function for the endpoint.
After this function is enabled, the endpoint automatically collects call information and generates session and media CHR data and periodically reports the media CHR data to eSight.
The default value is Disable.
CHR collection period (s)
Specifies the interval at which the endpoint collects CHR data.
The default value is 300.
CHR reporting period (s)
Specifies the interval at which the endpoint reports media CHR data to eSight.
The default value is 300.
- (Optional) Click Delete CHR Log to delete the CHR data files that have been sent to eSight.
- Click Save. The settings take effect immediately.