Online Help
OceanStor Dorado V6 Series 6.0.0
Checking Controller Enclosure BBUs
Controller enclosure backup battery units (BBUs) provide power failure protection for controller enclosures, allowing data to be saved in the event of a power failure. This section describes how to view controller enclosure BBU information to check its status.
Impact on the System
Controller enclosure BBUs provide power failure protection for controller enclosures, allowing data to be saved in the event of a power failure. If controller enclosure BBUs malfunction, cache data cannot be saved to disks upon power failure, resulting in data loss.
Reference Standard
If controller enclosure BBUs are working properly, the following items are true on DeviceManager:
- Health Status of BBUs is Normal, and Running Status is Online.
- No BBU alarm appears on the Current Alarms page.
Procedure
- Choose System > Hardware.
- Click the desired BBU.
The detailed information about the BBU is displayed.
- View the BBU information in the dialog box that is displayed.
Table 15-17 describes the parameters.
Table 15-17 BBU parametersParameter
Description
Health Status
Health status of the BBU. Possible values are:
- Normal: The functionality and operating performance of the BBU are normal.
- Faulty: The BBU is working improperly.
- Insufficient power: The power level of the BBU is low though its operating performance is normal.
Running Status
Running status of the BBU. Possible values are Online, Charging, and Discharging.
Discharges
Number of times when the BBU is discharged.
Firmware Version
Firmware version of the BBU.
Production Date
Production date of the BBU.
Electronic Label
Electronic label of the BBU.
Follow-up Procedure
If a BBU alarm appears on the Current Alarms tab page, select and handle the alarm according to its details and repair suggestions.