This document describes the configurations of Device Management, including device status query, hardware management, Information Center Configuration, NTP, Synchronous Ethernet Configuration, 1588v2 (PTP), Fault Management Configuration, Energy-Saving Management Configuration, Performance Management Configuration, Maintenance Assistant Configuration, OPS Configuration and PADS Configuration.
Configuring the Clock Link Mode for a Stack Member Port in a Stack
Context
To ensure clock or time synchronization between member switches in a stack, you must set the clock link mode of stack member ports to the interlink mode.
In a stack, after the clock link mode of stack member ports is set to the interlink mode, you still need to finish the subsequent synchronous Ethernet configuration, which is the same as the synchronous Ethernet configuration of a standalone switch.
Procedure
- Run system-view
The system view is displayed.
- Run interface interface-type interface-number
The interface view corresponding to a stack member port is displayed.
- Run clock link-mode interlink
The clock link mode is set to the interlink mode on the stack member port.
- The clock link mode of stack member ports on each stack member switch must be set to the interlink mode.
- Each chassis can have no more than two stack member ports configured as interlink ports. Clock source or other clock configuration commands cannot be configured on interlink ports.
- Run commit
The configuration is committed.