Atlas 900 Compute Node iBMC Alarm Handling 04

ALM-0x23000007 Failed to Read the Temperature of the Middle of the Air Inlet of the I/O Board (I/O Board, Minor Alarm)

ALM-0x23000007 Failed to Read the Temperature of the Middle of the Air Inlet of the I/O Board (I/O Board, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the middle part of the I/O board(arg1) air inlet temperature. 

This alarm is generated when the system failed to obtain the air inlet temperature in the middle part of the I/O board.

Alarm object: I/O board

Attribute

Alarm ID Alarm Severity Auto Clear

0x23000007

Minor

Yes

Parameters

Name Meaning

arg1

Location of the I/O board:
  • BIO
  • FIO

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.

Possible Causes

  • The iBMC is abnormal.
  • The I/O board is faulty.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Remove the power cable to power off the server, and then reconnect the power cable to power on the server. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Replace the I/O board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Contact technical support.