SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-M3 Series User Manual

M:SUN2000-20KTL-M3,SUN2000-20KTL-BRM3,SUN2000-29.9KTL-M3,SUN2000-30KTL-M3,SUN2000-30KTL-BRM3,SUN2000-36KTL-M3,SUN2000-40KTL-M3,SUN2000-40KTL-BRM3;Smart PV inverter, Smart PV Controller, Cascading, AFCI, Smart I-V Curve Diagnosis, dry contact scheduling, dry contact function, rapid shutdown

M:SUN2000-20KTL-M3,SUN2000-20KTL-BRM3,SUN2000-29.9KTL-M3,SUN2000-30KTL-M3,SUN2000-30KTL-BRM3,SUN2000-36KTL-M3,SUN2000-40KTL-M3,SUN2000-40KTL-BRM3;Smart PV inverter, Smart PV Controller, Cascading, AFCI, Smart I-V Curve Diagnosis, dry contact scheduling, dry contact function, rapid shutdown

Technical Specifications

Technical Specifications

Efficiency

Item

SUN2000-20KTL-M3

SUN2000-20KTL-BRM3

SUN2000-29.9KTL-M3

SUN2000-30KTL-M3

SUN2000-30KTL-BRM3

SUN2000-36KTL-M3

SUN2000-40KTL-M3

SUN2000-40KTL-BRM3

Maximum efficiency

97.1%

98.65%/400 V

98.75%/480 V

98.65%/400 V

98.75%/480 V

98.65%/400 V

98.75%/480 V

98.65%/400 V

98.75%/480 V

European efficiency

96.7%

98.4%/400 V

98.45%/480 V

98.4%/400 V

98.45%/480 V

98.4%/400 V

98.5%/480 V

98.4%/400 V

98.5%/480 V

Input

Item

SUN2000-20KTL-M3

SUN2000-20KTL-BRM3

SUN2000-29.9KTL-M3

SUN2000-30KTL-M3

SUN2000-30KTL-BRM3

SUN2000-36KTL-M3

SUN2000-40KTL-M3

SUN2000-40KTL-BRM3

Recommended maximum input DC power

30,000 W

44,850 W

45,000 W

54,000 W

60,000 W

Maximum input voltagea

800 V

1100 V

Maximum input current per MPPT circuit

27 A

Maximum short-circuit current per MPPT circuit

40 A

Minimum startup voltage

200 V

Operating voltage rangeb

200–750 V

200–1000 V

Full-load MPPT voltage rangec

300–550 V

500–800 V/400 V AC

625–850 V/480 V AC

500–800 V/(380 V AC, 400 V AC)

625–850 V/440 V AC

625–850 V/480 V AC

520–800 V/(380 V AC, 400 V AC)

625–850 V/440 V AC

625–850 V/480 V AC

540–800 V/(380 V AC, 400 V AC)

625–850 V/440 V AC

625–850 V/480 V AC

Rated input voltage

350 V

600 V/400 V AC

720 V/480 V AC

600 V/(380 V AC, 400 V AC)

650 V/440 V AC

720 V/480 V AC

600 V/(380 V AC, 400 V AC)

650 V/440 V AC 720 V/480 V AC

600 V/(380 V AC, 400 V AC)

650 V/440 V AC

720 V/480 V AC

Maximum number of inputs

8

Number of MPPT circuits

4

Note a: The maximum input voltage is the maximum DC input voltage that the inverter can withstand. If the input voltage exceeds this value, the inverter may be damaged.

Note b: If the input voltage is beyond the operating voltage range, the inverter cannot work properly.

Note c: The PV strings connecting to the same MPPT circuit shall use the same model and quantity of PV modules. It is recommended that the PV string voltage be higher than the lower threshold of the full-load MPPT voltage.

Output

Item

SUN2000-20KTL-M3

SUN2000-20KTL-BRM3

SUN2000-29.9KTL-M3

SUN2000-30KTL-M3

SUN2000-30KTL-BRM3

SUN2000-36KTL-M3

SUN2000-40KTL-M3

SUN2000-40KTL-BRM3

Rated output power

20,000 W

29,900 W

30,000 W

36,000 W

40,000 W

Maximum apparent power

22,000 VA

29,900 VA

33,000 VAa

40,000 VA

44,000 VA

Maximum active power (cosφ = 1)

22,000 W

29,900 W

33,000 Wa

40,000 W

44,000 W

Rated output voltageb

127 V AC/220 V AC,

230 V AC/400 V AC,

3W+(N)c+PE

230 V AC/400 V AC,

277 V AC/480 V AC,

3W+(N)c+PE

220 V AC/380 V AC,

230 V AC/400 V AC,

254 V AC/440 V AC,

277 V AC/480 V AC,

3W+(N)c+PE

220 V AC/380 V AC,

230 V AC/400 V AC,

254 V AC/440 V AC,

277 V AC/480 V AC,

3W+(N)c+PE

220 V AC/380 V AC,

230 V AC/400 V AC,

254 V AC/440 V AC,

277 V AC/480 V AC,

3W+(N)c+PE

Maximum output voltage at long-term operation

Refer to the local power grid standards.

Rated output current

52.5 A/220 V AC

28.9 A/400 V AC

43.2 A/400 V AC

36.0 A/480 V AC

45.6 A/380 V AC

43.3 A/400 V AC

39.4 A/440 V AC

36.1 A/480 V AC

54.7 A/380 V AC

52.0 A/400 V AC

47.3 A/440 V AC

43.3 A/480 V AC

60.8 A/380 V AC

57.8 A/400 V AC

52.5 A/440 V AC

48.1 A/480 V AC

Maximum output current

58.0 A/220 V AC

31.9 A/400 V AC

43.2 A/400 V AC

36.0 A/480 V AC

50.4 A/380 V AC

47.9 A/400 V AC

43.5 A/440 V AC

39.9 A/480 V AC

61.1 A/380 V AC

58.0 A/400 V AC

52.8 A/440 V AC (Mexico)

48.4 A/480 V AC

67.2 A/380 V AC

63.8 A/400 V AC

58.0 A/440 V AC (Mexico)

53.2 A/480 V AC

67.2 A/380 V AC

63.8 A/400 V AC

58.0 A/440 V AC (Mexico)

53.2 A/480 V AC

Output voltage frequency

50 Hz/60 Hz

Power factor

0.8 leading to 0.8 lagging

Output DC component (DCI)

< 0.5% of the rated output

Maximum total harmonic distortion

AC THDi

< 3% under rated conditions. Single harmonic meets the VDE 4105 requirements.

Note a: Under the German VDE-AR-N-4105, Belgium C10/11, and Austrian TOR grid codes, the SUN2000-30KTL-M3 has a maximum apparent power of 30000 VA and a maximum active power (cosφ=1) of 30000 W.

Note b: The rated output voltage is determined by Grid Codes, which can be set on the SUN2000 app, SmartLogger, or management system.

Note c: You can determine whether to connect the N wire based on the application scenario. In scenarios without N wires, set Output mode to Three-phase three-wire. In scenarios with N wires, set Output Mode to Three-phase four-wire.

Protection

Item

SUN2000-20KTL-M3

SUN2000-20KTL-BRM3

SUN2000-29.9KTL-M3

SUN2000-30KTL-M3

SUN2000-30KTL-BRM3

SUN2000-36KTL-M3

SUN2000-40KTL-M3

SUN2000-40KTL-BRM3

Overvoltage category

PV II/AC III

Input DC switch

Supported

Anti-islanding protection

Supported

Output overcurrent protection

Supported

Input reverse connection protection

Supported

PV string fault detection

Supported

DC surge protection

Type II

Type II

Type II

Type II/Type I (optional)

Type II

Type II/Type I (optional)

Type II/Type I (optional)

Type II

AC surge protection

Type II

Insulation resistance detection

Supported

Residual current monitoring unit (RCMU)

Supported

Display and Communication

Item

SUN2000-20KTL-M3

SUN2000-20KTL-BRM3

SUN2000-29.9KTL-M3

SUN2000-30KTL-M3

SUN2000-30KTL-BRM3

SUN2000-36KTL-M3

SUN2000-40KTL-M3

SUN2000-40KTL-BRM3

Display

LED indicators; WLAN+App

RS485

Supported

Built-in WLAN

Supported

AC MBUS

Not supported. Certain spare part models support this function. For details, contact the dealer.

DC MBUS

Supported

AFCI

Supported

PID recovery

Supported

General Specifications

Item

SUN2000-20KTL-M3

SUN2000-20KTL-BRM3

SUN2000-29.9KTL-M3

SUN2000-30KTL-M3

SUN2000-30KTL-BRM3

SUN2000-36KTL-M3

SUN2000-40KTL-M3

SUN2000-40KTL-BRM3

Dimensions (W x H x D)

640 mm x 530 mm x 270 mm

Net weight

43 kg

Operating ambient temperature

–25°C to +60°C (input derated when the temperature is above +45°C)

Relative humidity

0%–100%

Cooling mode

Natural convection

Maximum operating altitude

4000 m

Storage temperature

–40°C to +70°C

IP rating

IP66

Topology

Transformerless

Wireless Communication Specifications

Item

Inverter Built-in WiFi

WLAN-FE Smart Dongle

4G Smart Dongle

Frequency

2400–2483.5 MHz

SDongleA-05:

2400–2483.5 MHz

SDongleB-06-EU (WiFi):

2400–2483.5 MHz

SDongleB-06-EU (4G):

  • Supports LTE FDD: B1/B3/B5/B8.
  • Supports LTE TDD: B7/B20/B28/B38/B40/B41.
  • Supports GSM/GPRS/EDGE: 900 MHz/1800 MHz.

SDongleB-06-AU (WiFi):

2400–2483.5 MHz

SDongleB-06-AU (4G):

  • LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B28
  • LTE-TDD: B40
  • WCDMA: B1/B2/B5/B8
  • GSM: 850 MHz/900 MHz/1800 MHz/1900 MHz

Note: The SDongleB-06-EU applies only to Europe. The SDongleB-06-AU applies only to Australia.

Protocol standard

WLAN 802.11b/g/n

SDongleA-05:

WLAN 802.11b/g/n

SDongleB-06-EU (WiFi):

WLAN 802.11b/g/n

SDongleB-06-EU (4G):

  • Supports LTE FDD (with receive diversity): B1/B3/B5/B8.
  • Supports LTE TDD (with receive diversity): B7/B20/B28/B38/B40/B41.
  • Supports GSM: 900 MHz/1800 MHz.
  • Supports digital audio.

SDongleB-06-AU (WiFi):

WLAN 802.11b/g/n

SDongleB-06-AU (4G):

  • Supports LTE FDD (with receive diversity): B1/B2/B3/B4/B5/B7/B8/B28/B66.
  • Supports LTE-TDD (with receive diversity): B40.
  • Supports WCDMA: B1/B2/B4/B5/B8.
  • Supports GSM: 850/900/1800/1900 MHz.
  • Supports digital audio.

Note: The SDongleB-06-EU applies only to Europe. The SDongleB-06-AU applies only to Australia.

Bandwidth

20 MHz/40 MHz (optional)

20 MHz/40 MHz (optional)

LTE features:

  • Supports a maximum of 3GPP R8 non-CA Cat 4 FDD and TDD.
  • Supports 1.4 MHz/3 MHz/5 MHz/10 MHz/15 MHz/20 MHz RF bandwidth.
  • Supports MIMO in the downlink.
  • LTE FDD: maximum downlink rate of 150 Mbit/s and maximum uplink rate of 50 Mbit/s
  • LTE TDD: maximum downlink rate of 130 Mbit/s and maximum uplink rate of 30 Mbit/s

UMTS features:

  • Supports 3GPP R7 HSDPA+, HSDPA, HSUPA, and WCDMA.
  • Supports QPSK and 16QAM modulation.
  • HSDPA+: maximum downlink rate of 21 Mbit/s
  • HSUPA: maximum uplink rate of 5.76 Mbit/s
  • WCDMA: maximum downlink rate of 384 kbit/s and maximum uplink rate of 384 kbit/s

GSM features:

GPRS:

  • Supports GPRS multislot class 12.
  • Coding schemes: CS-1, CS-2, CS-3, and CS-4
  • Maximum downlink rate: 85.6 kbit/s; maximum uplink rate: 85.6 kbit/s

EDGE:

  • Supports EDGE multislot class 12.
  • Supports GMSK and 8-PSK modulation and coding schemes.
  • Downlink coding format: MCS 1–9
  • Uplink coding format: MCS 1–9
  • Maximum downlink rate: 236.8 kbit/s; maximum uplink rate: 236.8 kbit/s

Maximum transmit power

≤ 20 dBm EIRP

≤ 20 dBm EIRP

  • Class 4 (33 dBm±2 dB), EGSM900 frequency band
  • Class 1 (30 dBm±2 dB), DCS1800 frequency band
  • Class E2 (27 dBm±3 dB), EGSM900 8-PSK
  • Class E2 (26 dBm±3 dB), DCS1800 8-PSK
  • Class 3 (24 dBm+1/–3 dB), WCDMA frequency band
  • Class 3 (23 dBm±2 dB), LTE FDD frequency band
  • Class 3 (23 dBm±2 dB), LTE TDD frequency band
Translation
Favorite
Download
Update Date:2025-08-29
Document ID:EDOC1100164794
Views:264524
Downloads:13933
Average rating:3.0Points

Digital Signature File

digtal sigature tool