NetEngine AR5700, AR6700, and AR8000 Hardware Description

AR6710-H4T4X2Y7

AR6710-H4T4X2Y7

Overview

Table 3-71 Basic information about the AR6710-H4T4X2Y7
Item Details
Description AR6710-H4T4X2Y7 assembly chassis
Part Number 02355VGU
Model AR6710-H4T4X2Y7
First supported version V600R023C10

Appearance

Figure 3-42 Appearance of the AR6710-H4T4X2Y7

Components

Figure 3-43 Components of the AR6710-H4T4X2Y7

1. Two power module slots

Applicable power modules:

PDC260S12-CL

PAC300S12-CL (300W AC Power Module)

2. Two SRU/SPU slots

Applicable SRU:

SRU-700S

NOTE:
  • Dual SRUs are supported in V600R024C00 and later versions. In dual-SRU scenarios, the two SRUs must be of the same model.
  • In versions earlier than V600R024C00, the SRU-700S can be installed only in slot 10. In V600R024C00 and later versions, the SRU-700S can be installed in either of the two slots.
  • The SPU is not supported in the current version.

3. Fan module slot

4. Product model silkscreen

5. Ground point

6. Six SIC slots

7. One WSIC slot

-

-

Slot Layout

Figure 3-44 Slot Layout of the AR6710-H4T4X2Y7
Table 3-72 Slots on the AR6710-H4T4X2Y7
Slot Type Slot ID Slot Direction Remarks
SIC slot 1 Transverse Slot 1 and slot 2 are combined into new slot 2 (WSIC).
SIC slot 2 Transverse Slot 1 and slot 2 are combined into new slot 2 (WSIC).
SIC/MPU slot 3 Transverse

Slot 3 and slot 4 are combined into new slot 4 (WSIC).

NOTE:

The MPU is not supported in the current version.

SIC slot 4 Transverse Slot 3 and slot 4 are combined into new slot 4 (WSIC).
WSIC 6 Transverse

Only a WSIC card can be inserted in slot 6.

Slot number 5 is unavailable.

SIC/MPU slot 7 Transverse

Slot 7 and slot 8 are combined into new slot 8 (WSIC).

NOTE:

The MPU is not supported in the current version.

SIC slot 8 Transverse Slot 7 and slot 8 are combined into new slot 8 (WSIC).
SRU/SPU slot 9 Transverse
NOTE:

The SPU is not supported in the current version.

SRU/SPU slot 10 Transverse
NOTE:

The SPU is not supported in the current version.

Power module PWR1 Transverse -
Power module PWR2 Transverse -
Fan slot FAN1 Transverse -
Fan slot FAN2 Transverse -

Technical Specifications

Table 3-73 Technical specifications of the AR6710-H4T4X2Y7
Item Specification
Installation type Rack
Chassis height [U] 1 U
Dimensions without packaging (H x W x D) [mm(in.)]
  • Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.54 in.)
  • Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 467.8 mm (1.72 in. x 17.4 in. x 18.42 in.)
Dimensions with packaging (H x W x D) [mm(in.)] 190 mm x 590 mm x 780 mm (7.48 in. x 23.23 in. x 30.71 in.)
Weight with packaging [kg(lb)] 11.26 kg (24.82 lb)
Weight without packaging [kg(lb)] 5.8 kg (12.79 lb)
Number of service board slots 7
MIC slots (default/maximum) 0/0
SIC slots (default/maximum) 6/6
WSIC slots (default/maximum) 1/4
XSIC slots (default/maximum) 0/2
Redundant MPUs Supported
RPS input Not supported
PoE Not supported
IP rating IP20
MTBF [years] 177.04 years
MTTR [hours] 2 hours
Availability 0.999998710
Typical power consumption [W] 12.6 W
Maximum power consumption [W] 25.2 W
Power supply mode
  • AC/HVDC pluggable
  • DC pluggable
Number of power modules 2
Rated input voltage [V]

Rated AC input voltage: 100 V to 240 V, 50 Hz or 60 Hz

Rated DC input voltage: –48 V DC to –60 V DC

Input voltage range [V]

Maximum AC input voltage: 90 V to 264 V, 47 Hz to 63 Hz

Maximum DC input voltage: –38.4 V DC to –72 V DC

Maximum input current [A] 5 A
Maximum output power [W]

AC: 300 W

DC: 260 W

Redundant power supply
  • Double AC power modules (1+1 backup)
  • Double DC power modules (1+1 backup)
Types of fans Pluggable
Number of fan modules 2
Heat dissipation mode Air cooling
Airflow Left-to-right airflow
Noise at normal temperature (acoustic power) [dB(A)] 54.3 dB(A)
Long-term operating temperature [°C(°F)]

0°C to 45°C (32°F to 113°F)

NOTE:

When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Long-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)] < 5000 m (16404.2 ft.)
Storage temperature [°C(°F)] -40°C to +70°C (-40°F to +158°F)
Overtemperature alarm Supported
Translation
Favorite
Download
Update Date:2025-04-11
Document ID:EDOC1100213474
Views:119000
Downloads:1567
Average rating:0.0Points

Digital Signature File

digtal sigature tool