NetEngine AR600, AR6100, AR6200, and AR6300 Hardware Installation and Maintenance Guide
Powering On and Off the Router
Context
Before you power on the router, check and ensure the following:
- The power module is correctly connected.
- The input voltage is in the range of 90 V AC to 264 V AC.
Procedure
- Power on the router.
Turn on the power switch of the power supply system, and then turn on the power switch on the router to start the router.
After the router starts, check the STATUS indicator of the power module first. If this indicator is in normal state, check the other indicators of the router. Figure 7-15 describes the indicator states when the router is running normally.
Hardware Module
Indicator
Description
Power module
STATUS
Steady green: The output power is within the allowed range.
MPU
SYS
Slow blinking green: The system is running properly.
Fan module
STATUS
Slow blinking green: The fan module is running properly.
- Power off the router.
Powering off the router will interrupt all the services on the router. Exercise caution when you perform this operation.
Turn off the power switch on the router, and then turn off the power switch of the power supply system.