S110, S220, S310, S530, and S620 Hardware Description
S620-16X8YZ
Overview
Item | Details |
---|---|
Description | S620-16X8YZ (16*10GE SFP+ ports, 8*25GE SFP28 ports, expansion card slot, with 1*AC power module) |
Part Number | 98012580 |
Model | S620-16X8YZ |
First supported version | V600R024C10 |
Components
1 |
One RST button NOTICE:
To restore the factory settings and reset the device, hold down the button for at least 6 seconds. To reset the device, press the button. Resetting the device will cause service interruption. Exercise caution when you press the button. |
2 |
Sixteen GE/2.5GE/10GE SFP+ optical ports |
3 |
Eight GE/2.5GE/10GE/25GE SFP28 optical ports |
4 |
One console port |
5 |
One USB port |
6 |
One ETH management port |
7 |
Ground screw NOTE:
It is used with a ground cable. |
8 |
Card slot NOTE:
Applicable card: |
9 |
Fan module slot 1 NOTE:
Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
10 |
Fan module slot 2 NOTE:
Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
11 |
Power module slot 1 NOTE:
Applicable power modules: |
12 |
Power module slot 2 NOTE:
Applicable power modules: |
Ports
Port | Connector Type | Description | Available Components |
---|---|---|---|
GE/2.5GE/10GE SFP+ optical port | SFP+ | A GE/2.5GE/10GE SFP+ optical port sends and receives service data at 1 Gbit/s, 2.5 Gbit/s, or 10 Gbit/s. When a 10GE optical module is connected to a port, the port can automatically adjust its rate to 10 Gbit/s. When a GE optical module is connected to a port, the port can automatically adjust its rate to 1 Gbit/s. Before installing a 2.5GE optical module on a port, run the port mode 2.5G command to configure the port to work at 2.5 Gbit/s. |
|
GE/2.5GE/10GE/25GE SFP28 optical port | SFP28 | A GE/2.5GE/10GE/25GE SFP28 optical port sends and receives service data at 1 Gbit/s, 2.5 Gbit/s, 10 Gbit/s, or 25 Gbit/s. When a 25GE optical module is connected to a port, the port can automatically adjust its rate to 25 Gbit/s. When a 10GE optical module is connected to a port, the port can automatically adjust its rate to 10 Gbit/s. Before installing a 2.5GE optical module on a port, run the port mode 2.5G command to configure the port to work at 2.5 Gbit/s. Before installing a GE optical module or GE copper module on a port, run the port mode GE command to configure the port to work at 1 Gbit/s. |
|
Console port | RJ45 | The console port is connected to a console for on-site configuration. | |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. | |
USB port | USB 2.0 Type A | The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. |
USB flash drive |
Indicators and Buttons
The S620-16X8YZ has the same types of indicators as the S620-24T16X8Y2CZ. For details, see the S620-24T16X8Y2CZ.
Power Supply System
The switch can use a single power module or two power modules for 1+1 power redundancy. The power modules with fans and power modules without fans cannot be installed on the same switch.
Power Module |
Heat Dissipation |
Note |
---|---|---|
180 W AC power module (one delivered by default) |
No fan, natural heat dissipation |
180 W AC power module and 240 W DC power module can be used together. |
240 W DC power module |
No fan, natural heat dissipation |
|
400 W DC power module |
With fans, air cooling for heat dissipation |
600 W AC power module and 400 W DC power module can be used together. |
600 W AC power module |
With fans, air cooling for heat dissipation |
Heat Dissipation System
The switch uses pluggable fan modules for forced air cooling. Air flows in from the right and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 454.0 mm (1.72 in. x 17.4 in. x 17.87 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 145.0 mm x 650.0 mm x 550.0 mm (5.71 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] | 1 U |
Chassis material | Metal |
Weight without packaging [kg(lb)] | 6.0 kg (13.23 lb) |
Weight with packaging [kg(lb)] | 8.49 kg(lb) |
Typical power consumption [W] | 30% traffic under the ATIS standard and dual power modules:
|
Typical heat dissipation [BTU/hour] | 30% traffic under the ATIS standard and dual power modules:
|
Maximum power consumption [W] | 100% traffic under the ATIS standard and dual power modules:
|
Maximum heat dissipation [BTU/hour] | 100% traffic under the ATIS standard and dual power modules:
|
Static power consumption [W] | 50 W |
MTBF [years] | 81.40 years |
Availability | > 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 54.2 dBA |
Noise at normal temperature (acoustic pressure) [dB(A)] | 41.2 dBA |
Number of card slots | 1 |
Number of power slots | 2 |
Number of fans modules | 2 |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together on the same device. NOTE:
Power modules with fans and power modules without fans cannot be installed on the same device. |
Long-term operating temperature [°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Memory | 4 GB |
Flash memory | Physical space: 2 GB |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Supported |
RTC | Supported |
RPS input | Not supported |
Power supply surge protection [kV] |
|
Ingress protection level (dustproof/waterproof) | IP20 |
Types of fans | Pluggable |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction | Air intake from front and right and air exhaust from rear |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |