SUN5000-(150K-MG0-ZH,150K-MG0) User Manual
M:SUN5000-150K-MG0-ZH,SUN5000-150K-MG0;Smart PV inverter, Smart PV Controller, Cascading, rapid shutdown
M:SUN5000-150K-MG0-ZH,SUN5000-150K-MG0;Smart PV inverter, Smart PV Controller, Cascading, rapid shutdown
Technical Specifications
Efficiency
Item |
SUN5000-150K-MG0-ZH |
SUN5000-150K-MG0 |
---|---|---|
Maximum efficiency |
≥ 98.6% (380 V), ≥ 98.8% (480 V) |
≥ 98.6% (380 V/400 V), ≥ 98.8% (480 V) |
Efficiency in China |
≥ 98.2% (380 V), ≥ 98.4% (480 V) |
/ |
Efficiency in Europe |
/ |
≥ 98.3% (380 V), ≥ 98.4% (400 V), ≥ 98.6% (480 V) |
Input
Item |
SUN5000-150K-MG0-ZH |
SUN5000-150K-MG0 |
---|---|---|
Maximum input voltagea |
1100 V |
1100 V |
Operating voltage rangeb |
200–1000 V |
200–1000 V |
Minimum startup voltage |
200 V |
200 V |
Full-load MPPT voltage rangec |
540–800 V (380 V) 625–850 V (480 V) |
540–800 V (380 V/400 V) 625–850 V (480 V) |
Rated input voltage |
600 V (380 V), 720 V (480 V) |
600 V (380 V/400 V), 720 V (480 V) |
Maximum input current (per MPPT) |
48 A |
48 A |
Maximum input current (per PV string) |
23 A |
23 A |
Maximum short-circuit current (per MPPT) |
66 A |
66 A |
Number of inputs |
21 |
21 |
Number of MPPT circuits |
7 |
7 |
Note a: The maximum input voltage is the maximum DC input voltage that the inverter can withstand. If the input voltage exceeds this value, the inverter may be damaged. Note b: If the input voltage is beyond the operating voltage range, the inverter cannot work properly. Note c: The PV strings connecting to the same MPPT circuit shall use the same model and quantity of PV modules. It is recommended that the PV string voltage be higher than the lower threshold of the full-load MPPT voltage. |
Output
Item |
SUN5000-150K-MG0-ZH |
SUN5000-150K-MG0 |
---|---|---|
Rated output power |
150 kW |
150 kW |
Maximum apparent power |
165 kVA |
165 kVA |
Maximum active power (cosφ = 1) |
165 kW |
165 kW |
Rated output voltagea |
Phase voltage/Line voltage: 220/380 V, 277/480 V 3W + (N)b + PE |
Phase voltage/Line voltage: 220 V/380 V, 230 V/400 V, 277 V/480 V 3W + (N)b + PE |
Rated output current |
227.9 A (380 V) 180.4 A (480 V) |
227.9 A (380 V) 216.5 A (400 V) 180.4 A (480 V) |
Adapted power grid frequency |
50 Hz/60 Hz |
50 Hz/60 Hz |
Maximum output current |
250.7 A (380 V) 198.5 A (480 V) |
253.2 A (380 V) 240.5 A (400 V) 200.5 A (480 V) |
Power factor |
0.8 leading to 0.8 lagging |
0.8 leading to 0.8 lagging |
Maximum total harmonic distortion (rated power) |
< 1% (rated working conditions) |
< 1% (rated working conditions) |
Output DC component (DCI) |
< 0.5% of the rated current |
< 0.5% of the rated current |
Note a: The rated output voltage is determined by Grid code, and Grid code can be set on the SUN2000 app, SmartLogger, or management system. Note b: You can determine whether to connect the N wire to the SUN5000 based on the application scenario. In scenarios without N wires, set Output mode to Three-phase, three-wire. In scenarios with N wires, set Output mode to Three-phase, four-wire. |
Protection
Item |
SUN5000-150K-MG0-ZH |
SUN5000-150K-MG0 |
---|---|---|
Arc-fault circuit interrupter (AFCI) |
Supported |
Supported |
Built-in PID recovery |
Supported |
Supported |
Input DC switch |
Supported |
Supported |
Anti-islanding protection |
Supported |
Supported |
Output overcurrent protection |
Supported |
Supported |
Input reverse connection protection |
Supported |
Supported |
PV string fault detection |
Supported |
Supported |
DC surge protection |
Type II |
Type II/Type I (optional) |
AC surge protection |
Type II |
Type II |
Insulation resistance detection |
Supported |
Supported |
Residual current monitoring unit (RCMU) |
Supported |
Supported |
Overvoltage category |
PV II/AC III |
PV II/AC III |
Display and Communication
Item |
SUN5000-150K-MG0-ZH |
SUN5000-150K-MG0 |
---|---|---|
Display |
LED indicator, USB data cable + App |
|
RS485 |
Supported |
|
AC MBUS |
Supported |
|
Optimizer |
Supported |
General Specifications
Item |
SUN5000-150K-MG0-ZH |
SUN5000-150K-MG0 |
---|---|---|
Dimensions (W x H x D) |
1000 mm x 710 mm x 395 mm |
1000 mm x 710 mm x 395 mm |
Net weight (including hanging kits) |
102 kg |
102 kg |
Operating ambient temperature |
–25°C to +60°C |
–25°C to +60°C |
Cooling mode |
Smart air cooling |
Smart air cooling |
Operating altitude |
0–5000 m (derated when the altitude exceeds 4000 m) |
0–5000 m (derated when the altitude exceeds 4000 m) |
Relative humidity |
0%–100% RH |
0%–100% RH |
Input and output terminals |
DC input terminals: CT75A-1T-34/CT75A-1T-35 (AVIC JONHON) AC output terminals: waterproof terminal + OT/DT terminal |
DC input terminals: HH4SFD4TMS/HH4SMD4TMS (Amphenol) AC output terminals: waterproof terminal + OT/DT terminal |
IP rating |
IP66 |
IP66 |
Topology |
Transformerless |
Transformerless |
The SUN5000-150K-MG0 (01076635-012, 01076635-004, 01076635-018, and 01076635-012) complies with IEC 61000-3-12.