CE6885-48YS8CQ
CE6885-48YS8CQ (02355KTM)
Overview
Item | Details |
---|---|
Description | CE6885-48YS8CQ switch (48*25GE SFP28, 8*100GE QSFP28, Without Fan and Power Modules) |
Part Number | 02355KTM |
Model | CE6885-48YS8CQ |
First supported version | V300R023C00 |
Other part numbers | 02355KTN (CE6885-48YS8CQ switch (48*25GE SFP28, 8*100GE QSFP28, 2*AC Power Modules, 5*Fans, Port-side Intake)) 02355KTP (CE6885-48YS8CQ switch (48*25GE SFP28, 8*100GE QSFP28, 2*AC Power Modules, 5*Fans, Port-side Exhaust)) |
Short Name | CE6885 |
The switch does not support stacking and USB-based deployment.
Appearance
Figures in the document are for reference only, and the actual appearance of the devices may vary depending on the exact device model.
Version Mapping
The huge hardware mapping data is migrated to the Info-Finder hardware center, where you can easily obtain hardware mapping information.
The Info-Finder hardware center incorporates comprehensive hardware information and mapping data by sales regions, allowing you to quickly find desired information and filter the mapping data for more fine-grained data display.
Components
1. Ground screw |
2. Equipment serial number (ESN) and MAC address NOTE:
You can scan the code to view the ESN and MAC address of the switch. |
3. Console port |
4. ETH management port (RJ45) |
5. USB port |
6. Five Fan slots Applicable fan modules: |
7. Two Power supply slots Applicable power modules: |
8. Forty-eight 25GE SFP28/50GE SFP56 Ethernet optical ports |
9. Eight 100GE QSFP28/200GE QSFP56 Ethernet optical ports |
10. Three port-side mounting holes for mounting brackets |
11. Two middle mounting holes for mounting brackets |
12. Equipotential bonding Ground screws for a ground cable with a two-hole OT terminal |
13. Four power-supply-side mounting holes for mounting brackets |
- |
- |
Slot Layout
Slot Type | Slot ID | Slot Direction | Remarks |
---|---|---|---|
Power supply slots | - | Horizontal insertion | The switch has two power supply slots, in which pluggable power modules can be installed. A chassis can use one or two power modules. In particular, dual power modules provide higher reliability. The switch supports dual power modules working in 1+1 backup mode. When both power modules are working properly, each power module provides half of the power for the switch. If one power module fails, the other one provides full power for the switch. All power modules are hot swappable. |
Fan slots | - | Horizontal insertion | The switch has fan slots in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. It is recommended that fan modules be properly installed on a switch to ensure normal switch operating. Fan modules work in hot backup mode. If a fan module fails, the system can still work properly for a short period of time. However, you are advised to replace the faulty fan module immediately. All fan modules are hot swappable. |
Indicators
1. System status indicator |
2. Stack master/slave indicator |
3. ID indicator |
4. Service port indicator (25GE/50GE optical port) |
5. Service port indicator (100GE/200GE optical port) |
6. ETH management port indicator |
- |
- |
- |
- |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
SYS | System status indicator | Green | Steady off | The system is not running. |
Green | Fast blinking | The system is starting. | ||
Green | Slow blinking | The system is running normally. | ||
Red | Steady on | An exception occurs during device startup. | ||
MST | Stack master/slave indicator | - | Steady off | Reserved function. This function is not enabled. |
ID | ID indicator | Blue | Steady off | The ID indicator is disabled (default status). |
Blue | Steady on | The ID indicator can be turned on or off remotely to help field engineers find the device to maintain. | ||
- | Service port indicator (50GE/25GE optical port) | Green | Steady off | The port is not connected or has been shut down. |
Green | Steady on | A link has been established on the port. | ||
Green | Blinking | The port is sending or receiving data. | ||
- | Service port indicator (200GE/100GE optical port) | Green | Steady off | The port is not connected or has been shut down. |
Green | Steady on | A link has been established on the port. | ||
Green | Blinking | The port is sending or receiving data. | ||
L/A | Management port indicator | Green | Steady off | No link is established on the port. |
Green | Steady on | A link is established on the port. | ||
Green | Blinking | The port is sending or receiving data. |
Ports
Port | Connector Type | Description | Available Components |
---|---|---|---|
50GE/25GE SFP56 optical port | SFP56 | Port for inputting and outputting 50GE/25GE/10GE/GE optical signals By default, the port is a 25GE port and supports 10GE auto-sensing. You can run a command to change the port rate to 50 Gbit/s or 1 Gbit/s. Every eight ports (1 to 8, 9 to 16, 17 to 24, 25 to 32, 33 to 40, and 41 to 48) form a group. In versions earlier than V300R024C00, when the rate of a 25GE port is changed to 50 Gbit/s or 1 Gbit/s, the rate of the other seven ports in the same group needs to be changed together. In V300R024C00 and later versions, the rate of a single port in a group can be changed independently, but all ports in the port group support only two rates, which can be any of the following combinations: 50GE/25GE, 25GE/10GE, 25GE/GE, 10GE/GE. A high-speed port license is required to achieve the 50 Gbit/s port rate. |
25GE SFP28 optical module 10GE SFP+ to 10GE SFP+ AOC cable 25GE SFP28 to 25GE SFP28 AOC cable 10GE SFP+ to 10GE SFP+ high-speed cable 25GE SFP28 to 25GE SFP28 high-speed cable NOTE:
1. Support for optical modules: (1) GE/10GE/25GE optical modules and 10GE/25GE AOC cables are supported, but LRM and linear optical modules are not supported. (2) In the case of port-side air intake, downlink 25GE/50GE ports support 1000Base-SX/LX/EX/ZX, 10G-AOC/SR/LR/ER/ZR/BIDI, and 25G-AOC/SR. In V300R024C10 and later versions, 25G/10G-SR multi-GE and 25G-BIDI optical modules are supported. (3) In the case of port-side air exhaust, downlink 25GE/50GE ports support 1000Base-SX/LX/EX/ZX, 10G-AOC/SR/LR/BIDI, and 25G-AOC/SR. In V300R024C10 and later versions, 25G/10G-SR multi-GE and 25G-BIDI optical modules are supported. 2. Support for copper cables: 10GE 1/3/5 m passive copper cables and 10 m active copper cables, and 25GE 1/3/5 m passive copper cables are supported. 3. GE copper modules are supported and can work at 100M/1000M (full-duplex only, half-duplex not supported). In V300R024C10 and later versions, 10GE copper modules are supported and can work at 100M/1000M/10GE (full-duplex only, half-duplex not supported). The following limitations apply: (1) GE copper modules do not comply with rail transportation standard EN 50121-4 and cannot work in the following scenarios:
(2) Ethernet cables cannot be routed to outdoors. (3) Copper modules cannot be installed in ports directly above or below another copper module. |
200GE/100GE QSFP56 optical port | QSFP56 | Port for inputting and outputting 200GE/100GE/40GE optical signals 1. A 100GE port can be configured to operate at 40GE. Every two ports (1 and 2, 3 and 4, 5 and 6, and 7 and 8) form a group. When a port is split into 4 x 10GE or 4 x 25GE ports, the other port in the same group also needs to be split. 2. A 100GE port can be configured to operate at 200GE. Every two ports (1 and 2, 3 and 4, 5 and 6, and 7 and 8) form a group, and the rate of the two ports in the same group must be switched together. A high-speed port license is required to achieve the 200 Gbit/s port rate. In versions earlier than V300R024C00, a 200GE port can be split only into 4 x 50GE ports. In V300R024C00 and later versions, a 200GE port can also be split into 2 x 100GE (100GE: 2 x 50GE) ports, and the port rate can be reduced to 100GE (100GE: 2 x 50GE). In this case, the first port of the 2 x 100GE ports is used. A 200GE port can be split into 2 x 100GE ports (100GE: 2 x 50GE) only when an AOC is connected. It cannot be split when a copper cable is connected. |
NOTE:
1. Support for optical modules: (1) In the case of port-side air intake, uplink 100GE/200GE ports support 100G-AOC/SR4/DR/LR4/4WDM and 200G-AOC/SR4/FR4. When the ambient temperature ranges from 0°C to 35°C (32°F to 95°F), 100G-ZR4 is supported, but the device noise will exceed the threshold. (2) In the case of port-side air exhaust, uplink 100GE/200GE ports support 100G-AOC/SR4/DR/LR4 and 200G-AOC/SR4. 2. Support for copper cables: 40GE, 40GE 1-to-4 4x10GE, 100GE, 100GE 1-to-4 4x25GE, and 200GE copper cables are supported. If 200GE copper cables are used to interconnect with switches, only CloudEngine series data center switches can be interconnected. Before using 200GE copper cables to interconnect with servers, contact Huawei engineers for interconnection verification. |
Console port | RJ45 | The console port is connected to a console for on-site configuration.
|
|
ETH management port | RJ45 | The ETH management port (RJ45) is used to connect the device to a configuration terminal or network management workstation to configure the device locally or remotely.
|
Category-5 or higher category Ethernet cable |
USB port | USB | It can be used for log backup and USB-based deployment. This function is reserved. |
Supports USB 2.0 flash drives. |
Heat Dissipation System
The cooling system of the CloudEngine 6800 series switches uses front-to-back or back-to-front airflow depending on the airflow direction of the power modules and fan modules used.
- Front-to-back airflow: Power modules and fan modules with front-to-back airflow are identified by
. Air flows into the chassis from the power supply side and is exhausted from the port side, as shown in Figure 4-164(using a CE6866-48S8CQ-P chassis as an example).
- Back-to-front airflow: Power modules and fan modules with back-to-front airflow are identified by
. Air flows into the chassis from the port side and is exhausted from the power supply side, as shown in Figure 4-165(using a CE6866-48S8CQ-P chassis as an example).
Power modules and fan modules using forced air cooling on a switch must have the same airflow direction. If a switch adopts power modules with back-to-front airflow, the switch must use fan modules with back-to-front airflow as well.
Technical Specifications
Item | Specification |
---|---|
Dimensions with packaging (H x W x D) [mm (in.)] | 185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] |
|
Weight without packaging [kg (lb)] | 6.36 kg (14.02 lb), excluding optical modules, power modules, and fan modules |
Weight without packaging (full configuration) [kg (lb)] | 8.55 kg (18.85 lb) (including AC power modules and fan modules, excluding optical modules, calculated based on the heaviest model if multiple models are supported) |
Weight with packaging [kg (lb)] | 10.63 kg (23.43 lb) |
Weight with packaging (full configuration) [kg (lb)] | 12.82 kg (28.26 lb) |
Chassis height [U] | 1 U |
Installation Type | Cabinet Installation |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
CPU | 4-core, 1.4 GHz |
Memory | DRAM: 8 GB |
NOR Flash | 64 MB |
SSD Flash | 4GB SSD |
USB | It can be used for log backup and USB-based deployment. This function is reserved. |
Power supply mode |
|
Console port | RJ45 |
Downlink Service interface | 48 x 25GE SFP28/48 x 50GE SFP56 |
Uplink Service interface | 8 x 100GE QSFP28/8 x 200GE QSFP56 |
Service port supporting the stack function | Reserved function. This function is not enabled. |
RTC | Supported |
Typical power consumption [W] | 48 x 25GE + 8 x 100GE: 147 W (100% traffic load, copper cables on 24 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) 166 W (100% traffic load, short-distance optical modules on 24 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) |
Typical heat dissipation [BTU/hour] | 48 x 25GE + 8 x 100GE: 502 BTU/hr (100% traffic load, copper cables on 24 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) 566 BTU/hr (100% traffic load, short-distance optical modules on 24 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) |
Static power consumption [W] | 136 W |
Static heat dissipation [BTU/hour] | 464 BTU/hour |
Maximum power consumption [W] | 48 x 25G + 8 x 100G: 200 W (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 326 W (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules) |
Maximum heat dissipation [BTU/hour] | 48 x 25GE + 8 x 100GE: 682 BTU/hour (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 1112 BTU/hour (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules) |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] |
|
Rated output power [W] |
|
Certification |
|
Power supply surge protection [kV] | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fan modules | 5 |
Redundant fans | The device supports 4+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and power modules must have the same airflow direction. |
Availability | 0.9999948505 |
MTBF [year] | 44.34 years |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Front-to-back airflow: Average: 52.8 dB(A); max: 58.7 dB(A) Back-to-front airflow: Average: 51.3 dB(A); max: 59.0 dB(A) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Front-to-back airflow: Average: 69.5 dB(A); max: 76.0 dB(A) Back-to-front airflow: Average: 70.2 dB(A); max: 75.6 dB(A) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.) NOTE:
When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |
RTU License Supported | Yes. By default, 48 x 25GE ports can only work at the rate of 25 Gbit/s, and eight 100GE ports can only work at the rate of 100 Gbit/s. You can use the RTU license (BOM number: 88036EUQ) to increase the rate of 25GE ports to 50 Gbit/s and the rate of 100GE ports to 200 Gbit/s. |