S6700 Series Switches Hardware Description (V200)

S6730-H48X6C (02352FSF/02352FSF-003/02352FSF-007/02352FSF-009/02352FSF-011/02352FSF-012/02353FWL/02353FWL-003/02353FWL-005/02353FWL-006)

S6730-H48X6C (02352FSF/02352FSF-003/02352FSF-007/02352FSF-009/02352FSF-011/02352FSF-012/02353FWL/02353FWL-003/02353FWL-005/02353FWL-006)

Version Mapping

Table 4-210 lists the mapping between the S6730-H48X6C chassis and software versions.

Table 4-210 Version mapping

Series

Model

Software Version

S6730-H

S6730-H48X6C

02352FSF: V200R013C02 and later versions

02352FSF-003: V200R020C10 and later versions

02352FSF-007: V200R021C10SPC500 and later versions (If V200R021C00SPC100 is used, install V200R021SPH011 or a later patch.)

02352FSF-009: V200R021C10SPC600 and later versions (If V200R021C00SPC100 is used, install V200R021SPH013 or a later patch.)

02352FSF-011: V200R022C00 and later versions

02352FSF-012: V200R021C10SPC600 and later versions (If V200R021C00SPC100 is used, install V200R021SPH013 or a later patch.)

02353FWL: V200R013C02 and later versions

02353FWL-003: V200R020C10 and later versions

02353FWL-005: V200R021C10SPC500 and later versions (If V200R021C00SPC100 is used, install V200R021SPH011 or a later patch.)

02353FWL-006: V200R021C10SPC600 and later versions (If V200R021C00SPC100 is used, install V200R021SPH013 or a later patch.)

NOTE:

V200R021C01 is not supported.

Appearance and Structure

Figure 4-88 S6730-H48X6C appearance

1

Forty-eight 10GE SFP+ ports

2

Six 40GE/100GE QSFP28 optical ports

NOTE:

A QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.

For the S6730-H48X6C (part number: 02352FSF/02352FSF-003/02352FSF-007/02352FSF-009/02352FSF-011/02352FSF-012):

  • By default, the license is not loaded on a switch.
  • In V200R013C02, QSFP28 ports are 100GE ports.
  • In V200R019C00 and later versions, QSFP28 ports are 40GE ports. To use the 100GE rate, you need to purchase and activate a license.
  • After a switch is upgraded from V200R013C02 to V200R019C00 or a later version, QSFP28 ports are still 100GE ports. You can load a license to change the port rate.
  • To configure QSFP28 ports as 100GE ports, load and activate this license, run the assign port-speed 100GE [ slot slot-id | all ] or assign port-type 100GE [ slot slot-id | all ] command, and restart the switch.

    In versions earlier than V200R020C00, the command format is assign port-speed 100GE [ slot slot-id | all ].

    In V200R020C00 and later versions, the command format is assign port-type 100GE [ slot slot-id | all ].

For the S6730-H48X6C (part number: 02353FWL/02353FWL-003/02353FWL-005/02353FWL-006), the license has been activated and QSFP28 ports on these switches work as 100GE ports.

3

Ground screw

NOTE:
It is used with a ground cable.

4

SSD card slot

NOTE:

This slot is reserved for future use.

5

One console port

6

One ETH management port

7

One USB port

8

One PNP button

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

9

Fan module slot 1

10

Fan module slot 2

11

Fan module slot 3

12

Fan module slot 4

13

Power module slot 1

14

Power module slot 2

Port Description

10GE SFP+ optical port

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 4-211 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 4-211 Attributes of a 10GE SFP+ port

Attribute

Description

Connector type

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ae

Working mode

GE/10GE auto-sensing

40GE/100GE QSFP28 optical port

A 40GE/100GE QSFP28 optical port sends and receives service traffic at 40 Gbit/s or 100 Gbit/s. Table 4-212 describes the attributes of a QSFP28 optical port.
Table 4-212 Attributes of a QSFP28 optical port

Attribute

Description

Connector type

MPO/LC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ba

Console port

The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4-213.
Table 4-213 Attributes of a console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS-232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

ETH management port

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. Table 4-214 describes the attributes of an ETH management port.
Table 4-214 Attributes of an ETH management port

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3

Working Mode

10/100 Mbit/s auto-sensing

Maximum transmission distance

100 m

In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see "First Login to a Switch" in the Configuration Guide - Basic Configuration.

USB port

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

Indicator Description

Figure 4-89 Indicators on the S6730-H48X6C

Table 4-215 Description of indicators on the switch

No.

Indicator

Name

Color

Status

Description

1

SYS

System status indicator

-

Off

The system is not running.

Green

Fast blinking

The system is starting.

Green

Steady on

During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds.

Green

Slow blinking

The system is running normally.

Red

Steady on

The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated.

2

MST

Stack indicator

-

Off

The switch is not the master switch in a stack.

Green

Blinking

The switch is the master switch in a stack or a standalone switch.

3

ID

ID indicator

-

Off

The ID indicator is not used (default state).

Blue

Steady on

The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain.

4

-

Service port indicator (10GE optical port)

NOTE:

Each optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green).

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

Green

Off

The port is not connected or has been shut down.

Steady on

A link has been established on the port.

Yellow

Off

The port is not sending or receiving data.

Blinking

The port is sending or receiving data.

5

-

Service port indicator (40GE/100GE optical port)

NOTE:

Each optical port has one single-color indicator. Arrowheads show the positions of ports.

-

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

Blinking

The port is sending or receiving data.

6

L/A

ETH port indicator

-

Off

The ETH port is not connected.

Green

Steady on

The ETH port is connected.

Green

Blinking

The Eth port is sending or receiving data.

7

USB

USB-based deployment indicator

-

Off

  • No USB flash drive is connected to the switch.
  • The USB port is damaged.
  • The indicator is damaged.
  • The USB flash drive does not have any configuration file and cannot be used for deployment.
  • The switch has been upgraded using the USB flash drive and is restarting.

Green

Steady on

A USB-based deployment has been completed.

Green

Blinking

The system is reading data from a USB flash drive.

Yellow

Steady on

The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch.

Red

Blinking

An error has occurred when the system is executing the configuration file or reading data from the USB flash drive.

Power Supply Configuration

The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.

Heat Dissipation

The S6730-H48X6C uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.

This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 4-216 lists technical specifications of the S6730-H48X6C.

Table 4-216 Technical specifications

Item

Description

Memory (RAM)

4 GB

Flash

2 GB in total. To view the available flash memory size, run the display version command.

Mean time between failures (MTBF)

56.87 years

Availability

> 0.99999

Service port surge protection

N/A

Power supply surge protection

  • Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode
  • Using DC power modules: ±2 kV in differential mode, ±4 kV in common mode

Dimensions (H x W x D)

  • Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)
  • Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.4 in. x 17.6 in.)

Weight (with packaging)

9.2 kg (20.28 lb)

Stack ports

  • Any 10GE SFP+ ports (a maximum of 16 physical ports)
  • Any 40GE/100GE QSFP28 ports (a maximum of 6 physical ports)

RTC

Supported

RPS

Not supported

PoE

Not supported

Rated voltage range

  • AC input: 100 V AC to 240 V AC, 50/60 Hz
  • High-Voltage DC input: 240 V DC
  • DC input: -48 V DC to -60 V DC

Maximum voltage range

  • AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz
  • High-Voltage DC input: 190 V DC to 290 V DC
  • DC input: -38.4 V DC to -72 V DC

Maximum power consumption (100% throughput, full speed of fans)

291 W

Typical power consumption (30% of traffic load, tested according to ATIS standard)

165 W

Operating temperature

-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The switch cannot be started when the ambient temperature is lower than 0°C (32°F).

The operating temperature of the switch is -5°C to 40°C (23°F to 104°F) when it uses QSFP-100G-ER4 optical module.

Storage temperature

-40°C to +70°C (-40°F to +158°F)

Noise under normal temperature (27°C, sound power)

< 65 dB(A)

Relative humidity

5% to 95%, noncondensing

Operating altitude

0-5000 m (0-16404 ft.)

Certification

  • EMC certification
  • Safety certification
  • Manufacturing certification

Part number

02352FSF

02352FSF-003

02352FSF-007

02352FSF-009

02352FSF-011

02352FSF-012

02353FWL

02353FWL-003

02353FWL-005

02353FWL-006