Item | Details |
---|---|
Description | S7703 Main Control Unit D |
Part Number | 03034HXN |
Model | LSS7MCUD0001 |
Card Type | MPU |
Appearance
Version Mapping
Product | Product Model | First Supported Version | IDs of available slots | Limitations |
---|---|---|---|---|
S7700 | S7703 | V200R021C01 | 04–05 | ES1D2MCUD000 and LSS7MCUD0001 can be installed in the same chassis. After an active/standby switchover occurs in a chassis, fans in the chassis change to the intelligent speed adjustment mode. If you want the fans to run at a specific speed, run the set fan-speed command to set the fan speed after the switchover. |
S7700 | S7703 PoE | V200R021C01 | 04–05 | ES1D2MCUD000 and LSS7MCUD0001 can be installed in the same chassis. After an active/standby switchover occurs in a chassis, fans in the chassis change to the intelligent speed adjustment mode. If you want the fans to run at a specific speed, run the set fan-speed command to set the fan speed after the switchover. |
Indicators and Buttons
1. SYNC: Time and clock synchronization indicator NOTE:
The indicator is reserved. |
2. USB indicator |
3. RST button |
4. ACT: active/standby status indicator |
5. RUN/ALM: running status indicator |
- |
- |
- |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
SYNC | SYNC indicator | - | Off | The indicator is reserved for future use. |
USB | USB indicator | Green | Steady on | USB-based deployment of the card has been completed. |
Green | Fast blinking | The card is reading data from a USB flash drive. | ||
Yellow | Steady on | The card has finished reading data from the USB flash drive. You can remove the USB flash drive now. | ||
Red | Steady on | The card fails to connect to the network management system (NMS) or fails to register with the NMS. | ||
Red | Fast blinking | An error has occurred when the card is executing the configuration file or reading data from the USB flash drive. | ||
- | Off | No USB flash drive is connected to the card, the USB port on the card is damaged, or the indicator is damaged. | ||
ACT | Active/standby status indicator | Green | Steady on | The card is the active MCU. |
Green | Off | The card is the standby MCU. | ||
RUN/ALM | Running status indicator | Green | Steady on | The card is powered on. If the indicator is steady green for no more than 30 seconds, the CPU is being started. If the indicator is steady green for more than 30 seconds, the software is not running. |
Green | Slow blinking | The card software is running properly. | ||
Green | Fast blinking | The card software is starting. | ||
Red | Steady on | The card has failed and the fault requires manual intervention. | ||
Yellow | Steady on | The card is powered off. |
Silkscreen | Name | Description |
---|---|---|
RST | Reset button | Press this button to reset the card. |
Ports
1. Two BITS ports NOTE:
The ports are reserved. |
2. One console management port |
3. One ETH management port |
4. One USB port |
Port | Connector Type | Description | Available Components |
---|---|---|---|
BITS port | RJ45 | Two BITS ports (reserved). | - |
USB port | USB 2.0 Type A | One USB port. A USB flash drive can be inserted into this port to load the system software to the switch during device deployment. | USB flash drive |
Console port | RJ45 | You can connect to a configuration terminal through this port for onsite configuration. | |
ETH management port | RJ45 | One ETH management port (10M/100M BASE-TX auto-sensing). It can connect to a network port of a configuration terminal or network management workstation to set up a local or remote configuration environment. |
Functions and Features
Functions and Features | Description |
---|---|
Basic functions | The MPU integrates the main control unit and system maintenance unit. |
Redundancy backup | Supported Main control board is mandatory for switches. Each switch must be configured with one or two main control boards. When one main control board is configured for a switch, the main control board can be installed in either main control board slot of the switch. When two main control boards are configured, the two main control boards work in hot standby mode to improve reliability of the switch. The active and standby main control boards monitor the status of each other. If the active main control board fails, the standby main control board automatically becomes active to ensure uninterrupted services. |
Hot swapping | Supported Before removing the active card, perform an active/standby switchover. |
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | 19.9 mm x 194.5 mm x 430.4 mm (0.78 in. x 7.66 in. x 16.95 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 100 mm x 268 mm x 500 mm (3.94 in. x 10.55 in. x 19.69 in.) |
Weight without packaging [kg(lb)] | 1.10 kg (2.43 lb) |
Weight with packaging [kg(lb)] | 1.75 kg (3.86 lb) |
Typical power consumption [W] | 20 W |
Typical heat dissipation [BTU/hour] | 68.24 BTU/hour |
Maximum power consumption [W] | 21 W |
Maximum heat dissipation [BTU/hour] | 71.65 BTU/hour |
Memory | 2 GB (not expandable) |
Storage | NAND flash: 2 GB, built-in |