CE6810-32T16S4Q-LI
Version Mapping
Table 2-83 lists the mappings between the CE6810-32T16S4Q-LI and software versions.
Appearance and Structure
The figures in this document are for reference only.
1 |
Power supply slot 1 Applicable power modules:
|
2 |
Power supply slot 2 Applicable power modules:
|
3 |
Fan slot 1 Applicable fan modules:
|
4 |
Fan slot 2 Applicable fan modules:
|
5 |
Console port |
6 |
ETH management port (RJ45) |
7 |
Barcode label
NOTE:
This label is drawable, and you can pull it outward to view the ESN barcode and MAC address of the switch. |
8 |
USB port |
9 |
Thirty-two 10GBASE-T Ethernet electrical ports |
10 |
Sixteen 10GE SFP+ Ethernet optical ports Applicable modules and cables:
|
11 |
Four 40GE QSFP+ Ethernet optical ports NOTE:
A 40GE QSFP+ port can be split into four 10GE ports. |
12 |
Three port-side mounting holes for mounting brackets |
13 |
Four power-supply-side mounting holes for mounting brackets |
14 |
Ground screw |
Slot
Power supply slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).- When both power modules are working properly, they equally provide power for a chassis.
- When one power module fails, the other one provides all power required for a chassis.
Fan slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.
All fan modules are hot swappable.
Airflow
- Front-to-back airflow: The power modules and fan modules using front-to-back airflow are marked
or
. Air flows into the chassis from the power supply side and flows out from the port side, as shown in Figure 2-37 (CE5800 as an example).
- Back-to-front airflow: The power modules and fan modules using back-to-front airflow are marked
or
. Air flows into the chassis from the port side and flows out from the power supply side, as shown in Figure 2-38 (CE5800 as an example).
When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.
Indicators
The downlink service port indicators of the CE6810-32T16S4Q-LI are 10GE electrical port indicators and 10GE optical indicators, and other indicators are the same as those on the CE6850-48T4Q-EI. The CE6850-48T4Q-EI is used as an example here to describe the indicators.
Ports
10GBASE-T Ethernet Electrical Port
Attribute |
Description |
---|---|
Connector type |
RJ45 |
Standards compliance |
IEEE802.3an and IEEE802.3az |
Applicable cable |
Straight-through cable and crossover cable |
Working mode |
Supported rate: 100/1000 Mbit/s and 10 Gbit/s auto-sensing Full-duplex |
Maximum transmission distance |
100 m |
10GE SFP+ Ethernet Optical Port
40GE QSFP+ Ethernet Optical Port
Console Port
ETH Management Port (RJ45)
USB Port
A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.
Specifications
Item |
Description |
|
---|---|---|
Physical specifications |
|
|
Environment parameters |
Temperature |
|
Relative humidity |
5% RH to 95% RH, noncondensing |
|
Altitude |
< 5000 m (16404 ft.) |
|
Noise (sound pressure, 27°C) |
|
|
Power specifications |
Power source type |
AC/DC |
AC power input |
|
|
DC power input |
|
|
High-voltage DC power input |
Not supported |
|
Rated input current |
|
|
Chassis power consumption |
Maximum power consumption |
288 W |
Typical power consumption |
204 W (100% throughput, 3 m Ethernet cables on 32 ports, SFP+ high-speed copper cables on 16 ports, and QSFP+ high-speed copper cables on 4 ports, double power modules) |
|
Chassis heat dissipation |
Maximum heat dissipation |
983 BTU/hr |
Typical heat dissipation |
696 BTU/hr (100% throughput, 3 m Ethernet cables on 32 ports, SFP+ high-speed copper cables on 16 ports, and QSFP+ high-speed copper cables on 4 ports, double power modules) |
|
Surge protection |
Ethernet electrical ports: 2 kV in common mode Power module:
|
|
Heat dissipation |
Heat dissipation mode |
Air cooling |
Airflow |
Front-to-back or back-to-front, depending on the fan modules and power modules |
|
Reliability and availability |
Power module backup |
1+1 backup |
Fan module backup |
Not supported |
|
Hot swap |
Supported by all power modules and fan modules |
|
Mean time between failures (MTBF) |
46.04 years |
|
Mean time to repair (MTTR) |
1.84 hours |
|
Availability |
0.99999544092 |
|
Technical specifications |
Processor |
1.2 GHz, quad-core |
DRAM Memory |
2 GB |
|
NOR Flash |
16 MB |
|
NAND Flash |
512 MB |
|
Stack |
Service port supporting the stack function |
10GE electrical ports, 10GE optical ports, and 40GE optical ports |
Certification |
|
Ordering Information
Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.
Table 2-90 provides the ordering information.
Part Number |
Part Model |
Part Description |
---|---|---|
02350EWD |
CE6810-LI-F-B00 |
CE6810-32T16S4Q-LI Switch (32-Port 10G RJ45, 16-Port 10G SFP+, 4-Port 40G QSFP+, 2*AC Power Module, 2*FAN Box, Port-side Exhaust) |
02350EWE |
CE6810-LI-B-B00 |
CE6810-32T16S4Q-LI Switch (32-Port 10G RJ45, 16-Port 10G SFP+, 4-Port 40G QSFP+, 2*AC Power Module, 2*FAN Box, Port-side Intake) |
02350EWB |
CE6810-32T16S4Q-LI-F |
CE6810-32T16S4Q-LI Switch (32-Port 10G RJ45, 16-Port 10G SFP+, 4-Port 40G QSFP+, 2*FAN Box, Port-side Exhaust, Without Power Module) |
02350EWC |
CE6810-32T16S4Q-LI-B |
CE6810-32T16S4Q-LI Switch (32-Port 10G RJ45, 16-Port 10G SFP+, 4-Port 40G QSFP+, 2*FAN Box, Port-side Intake, Without Power Module) |
02350TJF |
CE6810-32T16S4Q-LI |
CE6810-32T16S4Q-LI Switch (32-Port 10G RJ45, 16-Port 10G SFP+, 4-Port 40G QSFP+, Without Fan Box and Power Module) |