HUAWEI USG6000 Series V100, V500 Hardware Guide

USG6507, USG6530

USG6507, USG6530

The USG6507, USG6530 has only AC models and no DC models and uses an integrated chassis that contains the fixed interface board, single power module, and built-in fan module. You can also add some optional modules, such as hard disk, additional power module, and expansion cards, to improve system reliability and add more ports.

Mapping

Table 2-43 lists the mapping between the USG6507, USG6530 hardware and software versions.

Table 2-43 Mapping between the hardware and software versions

Model

Software Version

USG6507

V100R001C30, V500R001C20, and later versions

USG6530

V100R001C20, V500R001C00, and later versions

Front Panel

Figure 2-31 illustrates the front panel of the USG6507, USG6530.

Figure 2-31 USG6507, USG6530 front panel

Name

Description

Slot numbering

Identifies the slot type and number, with 0 indicating the slot for the out-of-band MGMT port (GigabitEthernet 0/0/0), 1 the slot for the interface board, and 2 and 3 the WSIC slots.

Interfaces are numbered in the format of "interface type A/B/C", where:
  • A is the slot number of the interface card.
  • B is the daughter card number, which is 0 because no daughter card is installed now.
  • C is the interface number, which begins with 0 and is numbered from bottom to top and left to right.

Fixed interface board

The core component for system control and management. The interface board provides an out-of-band management port, console port, and USB port for management access. The interface board is built-in and cannot be removed.

Expansion slot

Provides two Wide Service Interface Card (WSIC) slots for expansion cards. Table 2-28 lists the supported expansion cards.

ESD jack

The equipment end of the wrist strap is inserted into the ESD jack. For the wrist strap to be effective, ensure that the device is already grounded.

The expansion slots on the USG6507, USG6530 support the expansion cards listed in Table 2-44.

Table 2-44 Supported expansion cards

Expansion Card

Description

8GE WSIC Interface Card

Provides eight gigabit RJ45 Ethernet ports.

2XG8GE WSIC Interface Card

Provides eight gigabit RJ45 ports and two 10-gigabit SFP+ ports.

8GEF WSIC Interface Card

Provides eight gigabit SFP ports.

4GE-BYPASS WSIC Card

Provides two electrical bypass links.

Fixed Interface Board

Figure 2-32 illustrates the fixed interface board panel of the USG6507, USG6530.

Figure 2-32 Fixed interface board panel of the USG6507, USG6530
Table 2-45 Interface description

Name

Description

MGMT port

Out-of-band 10/100/1000M RJ45 autosensing Ethernet management port. The interface number is GigabitEthernet 0/0/0 and the default IP address of the interface is 192.168.0.1.

You can connect this port to the network port or any reachable port on a PC through a network cable. Then, you can use Telnet to access the CLI or use a web browser to access the web UI to configure, manage, and maintain the USG.

NOTE:

The MGMT port cannot be used as a service port.

Console port (RJ45)

Console ports allow you to locally connect a PC to the device. You can use a console cable to connect the console port (RJ45) on the device to the COM port on your PC and use a serial port terminal program on your PC to access, configure, and manage the device.

USB 2.0 port

  • USB ports allow you to insert USB devices for system software upgrades. For details on upgrades through USB devices, refer to the Upgrade Guide delivered with the device.
  • USB ports allow you to insert 4G LTE data cards. For details on the 4G LTE data cards, refer to 4G LTE Data Card.

0 to 3 (RJ45)

NOTE:

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

Service ports. They are four 10/100/1000M autosensing Ethernet electrical ports numbered from GigabitEthernet 1/0/0 to GigabitEthernet 1/0/3.

4 to 5 (RJ45 + SFP)

NOTE:

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

Combo ports. Combo ports are logic ports. One combo port can work as a GE electrical interface or a GE optical port. Each combo port has only one internal forwarding port. When the electrical port is enabled, the optical port is disabled. When the optical port is enabled, the electrical port is disabled. The electrical and optical ports of a combo port use the same interface view, numbered from GigabitEthernet 1/0/4 to GigabitEthernet 1/0/5. By default, the combo port is used as an electrical port. You can use the combo enable { copper | fiber } command to set the working mode of combo ports according to network requirements. Each optical port supports a 100 Mbit/s eSFP Optical Module or a 1 Gbit/s eSFP Optical Module.

RST button

To restart the device, press the RST button. Ensure that the running configuration is saved before pressing the RST button.

The RST button can also be used to restore the default settings. To do so, press and hold down the RST button and power on the device. When the MODE indicator of the fixed interface board blinks (about 3 to 5 seconds later), release the button. The device then starts with the default configuration.

NOTE:

If the device has a hard disk installed, before pressing the RST button to reset, run the disk offline command in the user view. Wait about 30 seconds until the system indicates that the hard disk stops working and then press the RST button. Otherwise, the data may be lost or hard disk be damaged.

Table 2-46 Indicator description

Indicator

Name

Color

Status

Description

SYS

System indicator

Green

Steady on

The system is being powered on or restarted.

Green

Blink every two seconds (0.5 Hz)

The system is running normally.

Green

Blink twice every second (2 Hz)

The system is starting.

Green

Blink eight times every second (8 Hz)

The system software or configuration file is being upgraded.

-

Off

The system is faulty.

ALM

NOTE:

If the system starts with dual power modules but one power module is not powered on, the ALM indicator is steady red, but the system is operating properly.

ALM indicator

Red

Steady on

The system is faulty. For example, the power-on self test (POST), power voltage, or temperature is abnormal.

-

Off

The system is running normally.

PWR

Power indicator

Green

Steady on

The power module works properly.

-

Off

The power module is faulty or the power cable is disconnected.

HDD

HDD indicator

Green

Steady on

The hard disk is running.

Green

Blink

Data is being read from or written to the hard disk.

-

Off

The hard disk is not detected.

MODE

MODE indicator

Green

Steady on

Hot standby is not configured, or hot standby is configured but the device is the standby device in an active/standby mode or the hot standby mode is load balancing.

-

Off

Hot standby is configured in active/standby mode and the device is the standby device.

MGMT

MGMT indicator

Green

Steady on

The link is connected.

Green

Blink eight times every second (8 Hz)

Data is being sent or received.

-

Off

The link is disconnected or not properly connected.

-

LINK indicator

Green

Steady on

The link is connected.

-

Off

The link is disconnected.

-

ACT indicator

Yellow

Steady on

Data is being sent or received.

-

Off

No data is being sent or received.

-

Indicator for optical ports 4 to 5

Green

Steady on

The link of the port is connected.

Green

Blink

Data is being sent or received through the port.

-

Off

The link of the port is disconnected.

Rear Panel

Figure 2-33 illustrates the rear panel of the USG6507, USG6530.

Figure 2-33 USG6507, USG6530 rear panel

Name

Description

Slot numbering

Indicates the layout of the slots, including the slot number and module type.

Power modules (in slots PWR5 and PWR6)

Provides power input and distribution for the device. PWR5 is the standard power module, which is built-in and not pluggable. An optional PWR6 power module is supported to provide 1+1 power redundancy. When PWR5 is working, PWR6 is hot-swappable. For details, see 170 W AC Power Module.

Hard disk combination (in slot HDD4)

The device supports optional hard disk combination SM-HDD-SAS300G-B, SM-HDD-SAS600G-B or SM-HDD-SAS1200G-B. Hard disks are used to store logs and reports, and they can be purchased from Huawei if necessary. For details, see Hard Disk Combination SM-HDD-SAS300G-B, Hard Disk Combination SM-HDD-SAS600G-B and Hard Disk Combination SM-HDD-SAS1200G-B.

If no hard disk is installed, a filler panel must be installed on slot HDD4 to ensure normal air flow and keep out dust.

NOTICE:
  • The USG starts to support SM-HDD-SAS600G-B hard disk combination since V500R001C30SPC100. If you use SM-HDD-SAS600G-B hard disk combination on earlier versions, the SM-HDD-SAS600G-B hard disk combination will be identified as non-Huawei hard disks. You need to upgrade the software version.

  • The USG starts to support SM-HDD-SAS1200G-B hard disk combination since V500R001C50. If you use SM-HDD-SAS1200G-B hard disk combination on earlier versions, the SM-HDD-SAS1200G-B hard disk combination will be identified as non-Huawei hard disks. You need to upgrade the software version.

SN

The serial number that uniquely identifies the device. The SN of the device must be provided to the local technical support personnel of Huawei to apply for a license.

Protective ground terminal

The M4 OT terminal of the ground cable is connected to the protective ground terminal of the device, and the other terminal of the ground cable is connected to the ground point of the cabinet or workbench or the ground bar of the equipment room.

Power Supply System

By default, the USG6507, USG6530 has a built-in 150W AC power module, but you can optionally add a 170 W AC power module for 1+1 power redundancy.

The 150W AC power module converts AC power to DC power for the device. The power module is built-in and cannot be removed. Figure 2-34 illustrates the appearance of the AC power module.

Figure 2-34 Appearance of the 150W AC power module

Name

Description

OUTPUT (green)

  • Steady on: The output of the AC power module is normal.

  • Off: The output of the AC power module is abnormal or in protection state (except hiccup mode protection state, in which the indicator blinks).

Power switch

The power switch allows you to turn on or off the power output.

Power receptacle

Connects the C13 plug of the AC power cable.

Clip hole

The hole is used to install the power cable clip, which is used to bind and fix the power cable. The power cable clip is installed before shipment.

Table 2-47 lists the functions of the 150W AC power module.

Table 2-47 Functions of the 150W AC power module

Item

Description

Input undervoltage protection

Stops power output and automatically restores power output after the input voltage becomes normal.

Input overvoltage protection

Stops power output and automatically restores power output after the input voltage becomes normal.

Input overcurrent protection

Stops power output and does not automatically restore power output after the input current becomes normal.

Output current limiting protection

Intermittently provides output and automatically restores normal output after the output current falls within a normal range.

Output overvoltage protection

Intermittently stops output and automatically restores output after the overvoltage condition is removed.

Output short circuit protection

Intermittently provides output and automatically restores normal output after the output short circuit is removed.

Overtemperature protection

When the temperature of the power module reaches a preset threshold, the power module stops power output and will automatically restore power output after the temperature drops back to the normal range.

Heat dissipation

The power adapter does not have fans. The heat dissipation is provided by the fan module of the device.

Hot swap

Not Supported.

Table 2-48 lists the technical specifications of the 150W AC power module.

Table 2-48 Technical specifications of the 150W AC power module

Item

Description

Form

Built-in module

Input

Rated input voltage range

100 V AC to 240 V AC (50 Hz/60 Hz)

Maximum input voltage range

90 V AC to 264 V AC (47 Hz to 63 Hz)

Maximum input current

2.5 A

Output

Rated output voltage

12 V DC

Maximum output voltage range

11.64 V DC to 12.36 V DC

Maximum output current

12.5 A

Maximum output power

150 W

Heat Dissipation System

The USG adopts the automatic fan speed adjustment technology to monitor the temperature of key components. If the internal device temperature is higher than the specified value, the fan speed increases; when the temperature falls back to its normal range, the fan speed decreases. In this way, the fan module enables the device to run in normal temperature, ensuring device running security and reliability.

Figure 2-35 illustrates the air flow of the device. The air intake areas include the left side and the hard disk installation slot on the front side, and the air exhaust is on the right side. The built-in fan module locates at the air exhaust and cannot be removed.

Figure 2-35 System Air Flow

Technical Specifications

Table 2-49 lists the technical specifications of the USG6507, USG6530.

Table 2-49 USG6507, USG6530 technical specifications

Item

Description

Part number

  • USG6507-AC: 02350DWR
  • USG6507-BDL-AC: 02350EFF
  • USG6530-AC: 02359515
  • USG6530-BDL-AC: 02359516

System specifications

CPU

Multi-core 1.0 GHz processor

Memory

DDR3 4GB

Flash

16MB

CF card

2 GB

Hard disk

Optional hot-swappable 300GB, 600GB or 1200GB 2.5-inch SAS hard disk. The hard disk unit is hot-swappable, but the hard disk combination is not hot-swappable.

SPUB (the service engine)

Not supported

4G LTE data card

Supported

Dimensions and weight

Dimensions (Ha x Wb x D)

44.4 mm x 442 mm x 421 mm (1.75 in. x 17.4 in. x 16.57 in, 1 U)

Weight

Standard: 6 kg

Fully configured: 8 kg

Power consumption and heat consumption

Typical power consumption

43.4 W

Maximum power consumption

44.6 W

Typical heat consumption

148.0 BTU/hour

Maximum heat consumption

152.3 BTU/hour

Power specifications

AC model

Supported; 150 W built-in power module (default) and 170 W hotswappable power module (optional)

Rated input voltage (AC)

100 V to 240 V, 50 Hz/60 Hz

Maximum input voltage (AC)

90 V to 264 V, 47 Hz to 63 Hz

Maximum input current (AC)

2.5A

Maximum output power (AC)

150 W (default) or 170 W (optional)

DC model

Not supported

Heat dissipation

Fan module

Built-in fan module, cannot be removed.

Number of fans

5

Air flow (hot air flow, viewed facing the rear panel)

Intake on the front and left sides, exhaust on the right side

Port density

Out-of-band management port

1 (RJ45)

Console port

1 (RJ45)

USB 2.0 port

1

Service ports in standard configuration

  • 2 GE Combo ports
  • 4 10/100/1000M autosensing Ethernet electrical ports

Expansion slot

2×WSIC

Types of expansion cards

  • 8GE-WSIC-8×1GE RJ45 interface card
  • 2XG8GE-WSIC-8×1GE RJ45+2×10GE SFP+ interface card
  • 8GEF-WSIC-8×1GE SFP interface card
  • 4GE-BYPASS-WSIC-2×electrical links Bypass card

Environment specificationsc

System reliability

MTBF (year)

11.58

MTTR (hour)

1

Ambient temperature

Short-termd

Without hard disk: -5°C to 55°C

With hard disk(s)e: 5°C to 40°C

Long-term

Without hard disk: 0°C to 45°C

With hard disk(s)e: 5°C to 40°C

Storage ambient temperature

-40°C to 70°C

Operating ambient relative humidity

Without hard disk: 5% RH to 95% RH, non-condensing

With hard disk(s): 5% RH to 90% RH, non-condensing

Storage ambient relative humidity

Without hard disk: 5% RH to 95% RH, non-condensing

With hard disk(s): 5% RH to 90% RH, non-condensing

Altitude

Without hard disk: 5,000 m

With hard disk(s): 3,000 m

NOTE:
  • a. The height is 1 U (1 U = 1.75 inches, or about 44.45 mm), which is a height unit defined in International Electrotechnical Commission (IEC) 60297 standards.
  • b. The width does not include the size of mounting ears.
  • c. Temperature and humidity are measured 1.5 m above the floor and 0.4 m in front of the rack when no protection plate exists before or after the rack.
  • d. The short term operating conditions mean that the continuous operating period does not exceed 48 hours and the accumulative total period within a year does not exceed 15 days. If the continuous operating period exceeds 48 hours or the total period within a year exceeds 15 days, it is regarded as long term.
  • e. The ambient temperature change rate of a device with hard disk(s) is less than or equal to 20°C per hour.