Table 9-73 QSFP28-100G-BIDI specifications
Item | Value |
---|---|
Basic Information | |
Module name | QSFP28-100G-BIDI |
Part Number | 02313EEK |
Model | QSFP28-100G-BIDI |
Form factor | QSFP28 |
Optical port standard/type | 100G PAM4 BiDi |
Connector type | LC/DLC |
Optical fiber type | MMF |
Type of the end face of the ceramic ferrule on optical ports | PC or UPC |
Working case temperature [°C (°F)] | 10°C to 70°C (50°F to 158°F) |
Transmission rate [bit/s] | 100Gbit/s |
Target transmission distance [km] | Multi-mode (OM3) optical fiber (diameter: 50 μm): 70 m Multi-mode (OM4) optical fiber (diameter: 50 μm): 100 m |
Modal bandwidth [MHz*km] | Multimode (OM3) optical fiber: 2000 MHz*km Multimode (OM4) optical fiber: 4700 MHz*km |
Bit error ratio (BER) | 1e-12 |
Transmitter Optical Characteristics | |
Center wavelength [nm] | 850 nm/910 nm |
Maximum Tx optical power (AVG) [dBm] | 4 dBm |
Minimum Tx optical power (AVG) [dBm] | -4.4 dBm |
Maximum Tx optical power (OMA) [dBm] | 3 dBm |
Minimum Tx optical power (OMA) [dBm] | -2.4 dBm |
Minimum extinction ratio [dB] | 3 dB |
Receiver Optical Characteristics | |
Rx sensitivity (AVG) [dBm] | -7.9 dBm |
Rx sensitivity (OMA) [dBm] | -5.9 dBm |
Overload power (AVG) [dBm] | 3.5 dBm |
Functions and Features | |
DDM options | Supported |
- Version support:
- V200R005C20 and V200R019C10 after the corresponding patch is installed
- V200R020C10 and later versions
- Before installing a QSFP28-100G-BIDI optical module on a port, you need to disable the FEC function on the port. For example, if the RS-FEC function is enabled on a port that has a QSFP28-100G-BIDI optical module installed, the port status will become Down (Transceiver type mismatch).
- BIDI optical modules must be used in pairs, QSFP-100G-BIDI-G2 cannot be used with QSFP28-100G-BIDI.