HiSecEngine USG6000F Series Hardware Guide

USG6710F

USG6710F

Overview

Table 3-156 Basic information about the USG6710F
Description Part Number Model First supported version Remarks
USG6710F-AC-(HTM) host(2*QSFP28 + 2*QSFP+ + 8*ZSFP+ + 20*SFP+ , 2 AC POWER) 02354TPX USG6710F-AC V600R021C10 -
USG6710F-AC-(HTM) host(2*QSFP28 + 2*QSFP+ + 8*ZSFP+ + 20*SFP+ , 2 AC POWER) 02354TPX-001 USG6710F-AC V600R021C10SPC100
  • If the device is used in V600R021C10SPC100, install V600R021SPH020 or a later patch.
  • Unsupported version: V600R021C10SPC600

Appearance

Figure 3-149 Appearance of the USG6710F (front view)
Figure 3-150 Appearance of the USG6710F (rear view)

Structure

Figure 3-151 Components of the USG6710F

1. Product series ID

2. Indicator and button area

3. HDD/SSD slot

4. Fixed interface area

5. Protective ground terminal

6. MAC label

7. SN label

8. Fan module

9. Power module

-

Table 3-157 Component functions

Name

Description

Product series ID

Indicates the product series of the device. For details about the product model, see the nameplate in the lower part of the device.

Indicator and button area

Provides multiple indicators to display the running status of the device in real time and provides the RST and OFL buttons for emergency maintenance.

HDD/SSD slot

Houses hard disks for storing log and report data.

Fixed interface area

Provides service ports, USB ports, console ports, and out-of-band management ports for device configuration and maintenance.

Protective ground terminal

Connects the M4 OT terminal of a PGND cable to the cabinet or the ground bar in the equipment room.

MAC label

Uniquely identifies the MAC address of the device, which is required during network forwarding configuration.

SN label

Uniquely identifies the device, which needs to be provided for the local technical support personnel to apply for a license.

Fan module

Dissipates heat for the device and is swappable. The fan module can be removed for no more than 1 minute.

Power module

Provides power input and distribution for the device. Two power modules are included in the standard configuration to provide 1+1 power redundancy. When one power module is running properly, the other one is hot swappable.

Slot Layout

Figure 3-152 Slot Layout of the USG6710F
Table 3-158 Slots on the USG6710F
Slot Type Slot ID Slot Direction Remarks
Hard disk (HDD/SSD) slot - Horizontal 2.5-inch SATA hard disks can be configured.
Fan module (FAN) slot Slots 1 to 4 Horizontal At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Power module (PWR) slot Slots 1 and 2 Horizontal Power modules are plug-and-play.

Indicators and Buttons

Figure 3-153 Indicators and Buttons of the USG6710F

1. PWR, SYS, USB, HA, WAN and CLOUD indicators

2. OFL indicator

3. BLE indicator

4. Optical port indicator

5. 10GE/GE optical port ACT indicator

6. 10GE/GE optical port LINK indicator

7. MGMT port indicator

8. RST button

9. OFL button

-

Arrowheads of optical ports show the positions of the ports. A down arrowhead indicates a port in the upper part, and an up arrowhead indicates a port in the lower part.

Table 3-159 Indicators on the USG6710F
Silkscreen Name Color Status Description
PWR Power indicator Green Steady on The power module is working properly.
- Off The power module is faulty or the device is not powered on.
SYS SYS indicator Green Steady on The system is being powered on or restarted.
Green Blinks once every 2 seconds (0.5 Hz). The system is running normally.
Green Blinking four times every second (4 Hz) The system is starting.
Red Steady on
  • The system is faulty.
  • The power supply is abnormal.
  • The fan module is abnormal.
NOTE:

If the system starts with two power modules and one power module is not powered on, the SYS indicator is steady red, but the system is running properly.

- Off The system is not running.
USB USB indicator Green Steady on USB-based deployment has been completed.
Green Blinking four times every second (4 Hz) The system is reading data from the USB flash drive.
Red Steady on USB-based deployment fails.
- Off USB-based deployment is disabled (default state).
HA HA indicator Green Steady on Hot backup, managing the master device
Green Blinks once every 2 seconds (0.5 Hz). Hot backup, managing the slave device
Red Steady on Dual-system hot backup is faulty.
- Off The dual-system hot backup function is disabled.
WAN WAN indicator - Off Reserved function. This function is not enabled.
CLOUD CLOUD indicator - Off Reserved function. This function is not enabled.
- OFL indicator Green Steady on The hard disk can be removed.
- Off The hard disk cannot be removed.
BLE BLE indicator - Off Reserved function. This function is not enabled.
- Optical port indicator Green Steady on The port link is connected.
Green Blinking (12 Hz) The port is sending or receiving data.
- Off No link is established on the port.
- ACT indicator of the optical port Yellow Blinking (12 Hz) Data is being transmitted or received.
- Off No data is being transmitted or received.
- LINK indicator of an optical port Green Steady on A link has been established.
- Off No link is established.
- MGMT port indicator Green Steady on A link has been established.
Green Blinking (12 Hz) The port is sending or receiving data.
- Off No link is established on the port.
Table 3-160 Buttons on the USG6710F
Silkscreen Name Description
RST RST button

To restart the device, press the RST button. Ensure that the running configuration is saved before pressing the RST button.

This button enables you to restore the default settings with one click. To be specific, you can press and hold down the RST button for 5 seconds and then release it to restore the default settings and restart the device.

OFL OFL button To remove a hard disk, press and hold the OFL button for 4 seconds until the OFL indicator turns on.

Ports

Figure 3-154 Ports of the USG6710F

1. HDD/SSD slot

2. 100GE/40GE optical port

3. 25GE/10GE optical port

4. 40GE optical port

5. 10GE optical port

6. 10GE/GE optical port

7. Console port

8. MGMT port

9. USB port

-

Table 3-161 Ports on the USG6710F
Port Connector Type Description Available Components
HDD/SSD slot - Hard disks are optional and can be purchased from Huawei if necessary.
NOTE:

In V600R022C00 and later versions, SSD-SATA240G-C and SSD-SATA960G-C hard disks are supported.

100GE/40GE optical ports (0 to 1) QSFP28

Two 100GE/40GE auto-sensing Ethernet optical ports numbered from 100GE0/0/0 to 100GE0/0/1.

A 100GE/40GE port works at 100 Gbit/s by default and can work at 40 Gbit/s when it has a 40GE optical module installed.

25GE/10GE optical ports (0 to 7) SFP28

The 25GE/10GE and 100GE/40GE optical ports are multiplexed. Four 25GE/10GE ports correspond to one 100GE/40GE port (25GE/10GE ports 0 to 3, and ports 4 to 7 correspond to 100GE/40GE ports 0 and 1, respectively). 25GE/10GE optical ports and 100GE/40GE optical ports that are multiplexed cannot work at 25 Gbit/s and 100 Gbit/s simultaneously.

By default, 25GE/10GE ports work at 10 Gbit/s and are numbered from 10GE0/0/0 to 10GE0/0/7.

To configure a 25GE/10GE port to work at 25 Gbit/s, run the port mode 40GE interface 100GE0/0/x command.

After the rate mode is switched, the 25GE/10GE port works at 25 Gbit/s when it has a 25GE optical module installed and can also work at 10 Gbit/s when it has a 10GE optical module installed. In addition, the corresponding 100GE/40GE ports can work normally only when they have 40GE optical modules installed. They cannot work normally when they have 100GE optical modules installed.

NOTE:
  • The port mode 40GE interface 100GE0/0/x command does not support multi-port operations. x indicates the number of a port.
  • After the command is executed, a new port number is generated. That is, the port numbers 10GE0/0/x to 10GE0/0/x change to 25GE0/0/x to 25GE0/0/x, and the port number 100GE0/0/x changes to 40GE0/0/x. After the rate is changed, you can run the undo port mode 40GE interface 100GE0/0/x command to restore the original rate.
  • After the rate is changed, the number of available ports remains unchanged.
40GE optical ports (2 to 3) QSFP+ Two 40GE Ethernet optical ports numbered from 40GE0/0/2 to 40GE0/0/3.

40Gbps QSFP+ Optical Modules

10GE optical ports (8 to 15) SFP+ Eight 10GE optical ports numbered from 10GE0/0/8 to 10GE0/0/15.
10GE/GE optical ports (16 to 27) SFP+ Twelve 10GE auto-sensing Ethernet optical ports numbered from 10GE0/0/16 to 10GE0/0/27. They can also be used as GE optical ports.
Console port RJ45 The console port is connected to a console for on-site configuration. You can use a console cable to connect the console port (RJ45) on the device to the COM port on your PC and use the terminal emulation program on the PC to access the CLI of the device to configure, manage, and maintain the device.

Console Cable

MGMT port RJ45

The out-of-band management port is a 10/100/1000M RJ45 autosensing Ethernet port. The port number is MEth0/0/0 and the default IP address is 192.168.0.1.

You can connect this port to the network port or any reachable port on a PC through an Ethernet cable. Then, you can use STelnetv2 to access the CLI of the device or use the web browser to access the web UI to configure, manage, and maintain the device.

NOTE:

The MGMT port cannot be used as a service port.

Ethernet Cable

USB USB Type A USB ports allow you to insert USB devices for system software upgrades. For details about the upgrade through a USB flash drive, see the Upgrade Guide delivered with the version.
  • USB 2.0-compliant USB flash drive
  • USB 3.0-compliant USB flash drive

Power Supply System

The power supply system has two PAC600S12-PB AC power modules for 1+1 power redundancy.

Heat Dissipation System

The heat dissipation system consists of four FAN-036A-B modules working in 3+1 backup mode. From the front panel, the device provides a front-to-rear air flow. The fan module locates at the air exhaust of the system.

Figure 3-155 System air flow of the USG6710F

Technical Specifications

Table 3-162 Technical specifications of the USG6710F
Item Specification
Installation Type Rack
Cabinet installation standard Cabinet with a depth of 800 mm or above
Dimensions without packaging (H x W x D) [mm(in.)]
  • Typical dimensions (excluding the parts protruding from the body): 43.6 mm x 442 mm x 600 mm (1.72 in. x 17.40 in. x 23.62 in.)
  • Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442 mm x 633 mm (1.72 in. x 17.40 in. x 24.92 in.)
Dimensions with packaging (H x W x D) [mm(in.)] 260 mm x 590 mm x 790 mm
Chassis height [U] 1 U
Weight with packaging [kg(lb)] 15.48 kg (34.13 lb)
Weight without packaging [kg(lb)] 10.26 kg (22.62 lb)
CPU 2 CPUs, 16 cores/CPU, 2.0 GHz dominant frequency
Memory 64 GB DDR4 ECC DIMM, 32 GB/CPU
Storage 32GB
NOR Flash 64 MB/CPU, 128 MB in total
Hard disk Optional. You can purchase a 2.5-inch SATA hard disk from Huawei based on the site requirements. The hard disk is hot swappable. For details, see the description of HDD and SDD in Storage Devices > Hard Disk.
Console port RJ45
Eth Management port RJ45
Typical power consumption [W] 257 W
Typical heat dissipation [BTU/hour] 876.9 BTU/hour
Maximum power consumption [W] 391 W
Maximum heat dissipation [BTU/hour] 1334.1 BTU/hour
MTBF [years] 35.14 years
MTTR [hours] 1 hours
Availability 0.999997
Power supply mode AC pluggable
Number of power modules 2
Redundant power supply 1+1
Rated input voltage [V]
  • AC: 100 V to 240 V, 50 Hz/60 Hz
  • High-voltage DC: 240 V, DC
Input voltage range [V]
  • AC: 90 V to 290 V, 45 Hz to 65 Hz
  • High-voltage DC: 190–290 V, DC
Maximum input current [A] 8 A/power module
Rated output power [W] 600W/12V
Maximum output power [W] 600 W/power module
Types of fans Pluggable
Number of fan modules 4
Automatic fan speed adjustment Supported
Heat dissipation mode Absorbing cold air into the device
Airflow direction Front-to-back airflow
Redundant fans 3+1
PoE Not supported
Noise at normal temperature (acoustic power) [db(A)] ≤72dB(A)
Long-term operating temperature [°C(°F)]
  • Without HDDs: 0°C to 45°C (32°F to 113°F)
  • With HDDs: 5°C to 40°C (41°F to 104°F)
Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)
Long-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Storage relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)]
  • Without HDDs: 0 m to 5000 m (0 ft to 16404 ft)
  • With HDDs: 0 m to 3000 m (0 ft to 9843 ft)
Storage altitude [m(ft.)] 0 m to 5000 m (0 ft to 16404 ft)
  • The width does not include the size of mounting ears.
  • The height is 1U (1U = 1.75 inches, or about 44.45 mm), which is a height unit defined in International Electrotechnical Commission (IEC) 60297 standards.
  • Temperature and humidity are measured 1.5 m above the floor and 0.4 m in front of the rack when no protection plate exists before or after the rack.
  • The operating temperature change rate of a device with HDDs must be less than or equal to 20°C/hour.
Translation
Favorite
Download
Update Date:2025-07-29
Document ID:EDOC1100208764
Views:136897
Downloads:3189
Average rating:4.5Points

Digital Signature File

digtal sigature tool