HiSecEngine USG6000F Series Hardware Guide
USG6655F
Overview
Description | Part Number | Model | First supported version |
---|---|---|---|
USG6655F(HTM) AC Host(8*GE COMBO + 4*GE RJ45 + 10*10GE SFP+ ,2 AC POWER) | 02353WAW | USG6655F-AC | V600R020C10 |
Appearance
Structure
1. Product series ID |
2. Indicator and button area |
3. HDD/SSD slot |
4. Fixed interface area |
5. Protective ground terminal |
6. MAC label |
7. SN label |
8. Slot ID |
9. Expansion slot |
10. Fan module |
11. Power module |
- |
- |
- |
- |
Name |
Description |
---|---|
Product series ID |
Indicates the product series of the device. For details about the product model, see the nameplate in the lower part of the device. |
Indicator and button area |
Provides multiple indicators to display the running status of the device in real time and provides the RST and OFL buttons for emergency maintenance. |
HDD/SSD slot |
Houses hard disks for storing log and report data. |
Fixed interface area |
Provides service ports, USB ports, console ports, and out-of-band management ports for device configuration and maintenance. |
Protective ground terminal |
Connects the M4 OT terminal of a PGND cable to the cabinet or the ground bar in the equipment room. |
MAC label |
Uniquely identifies the MAC address of the device, which is required during network forwarding configuration. |
SN label |
Uniquely identifies the device, which needs to be provided for the local technical support personnel to apply for a license. |
Slot ID |
Slot arrangement mode and number of the device. |
Expansion slot |
The provides expansion slots for installing expansion cards. When no expansion card is installed in the slot, install a filler panel on the vacant slot to ensure normal air flow and keep out dust. |
Fan module |
Dissipates heat for the device and is swappable. The fan module can be removed for no more than 1 minute. |
Power module |
Provides power input and distribution for the device. Two power modules are included in the standard configuration to provide 1+1 power redundancy. When one power module is running properly, the other one is hot swappable. |
Slot Layout
Slot Type | Slot ID | Slot Direction | Remarks |
---|---|---|---|
Hard disk (HDD/SSD) slot | - | Horizontal | 2.5-inch SATA hard disks can be configured. |
Expansion card slot | Slots 1 and 2 | Horizontal | The SIC-2SM-BF and SIC-4GE-BC cards are supported. NOTE:
The SIC-4GE-BC card is supported in V600R022C10 and later versions. |
Fan module (FAN) slot | Slots 1 to 4 | Horizontal | At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Power module (PWR) slot | Slots 1 and 2 | Horizontal | Power modules are plug-and-play. |
Indicators and Buttons
1. PWR, SYS, USB, HA, WAN and CLOUD indicators |
2. OFL indicator |
3. GE electrical port indicator |
4. Optical port ACT indicator |
5. Optical port LINK indicator |
6. MGMT port indicator |
7. RST button |
8. OFL button |
- |
- |
- GE electrical interface indicators from left to right correspond to GE electrical interfaces in ascending order. For example, the first indicator on the panel corresponds to GE0/0/0 and the second indicator corresponds to GE0/0/1.
- Arrowheads of optical ports show the positions of the ports. A down arrowhead indicates a port in the upper part, and an up arrowhead indicates a port in the lower part.
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
PWR | Power indicator | Green | Steady on | The power module is working properly. |
- | Off | The power module is faulty or the device is not powered on. | ||
SYS | SYS indicator | Green | Steady on | The system is being powered on or restarted. |
Green | Blinks once every 2 seconds (0.5 Hz). | The system is running normally. | ||
Green | Blinking four times every second (4 Hz) | The system is starting. | ||
Red | Steady on |
NOTE:
If the system starts with two power modules and one power module is not powered on, the SYS indicator is steady red, but the system is running properly. |
||
- | Off | The system is not running. | ||
USB | USB indicator NOTE:
This indicator has been supported since V600R021C00. |
Green | Steady on | USB-based deployment has been completed. |
Green | Blinking four times every second (4 Hz) | The system is reading data from the USB flash drive. | ||
Red | Steady on | USB-based deployment fails. | ||
- | Off | USB-based deployment is disabled (default state). | ||
HA | HA indicator | Green | Steady on | Hot backup, managing the master device |
Green | Blinks once every 2 seconds (0.5 Hz). | Hot backup, managing the slave device | ||
Red | Steady on | Dual-system hot backup is faulty. | ||
- | Off | The dual-system hot backup function is disabled. | ||
WAN | WAN indicator | - | Off | Reserved function. This function is not enabled. |
CLOUD | CLOUD indicator | - | Off | Reserved function. This function is not enabled. |
- | OFL indicator | Green | Steady on | The hard disk can be removed. |
- | Off | The hard disk cannot be removed. | ||
- | GE electrical port indicator | Green | Steady on | The port link is connected. |
Green | Blinking (12 Hz) | The port is sending or receiving data. | ||
- | Off | No link is established on the port. | ||
- | ACT indicator of the optical port | Yellow | Blinking (12 Hz) | Data is being transmitted or received. |
- | Off | No data is being transmitted or received. | ||
- | LINK indicator of an optical port | Green | Steady on | A link has been established. |
- | Off | No link is established. | ||
- | MGMT port indicator | Green | Steady on | A link has been established. |
Green | Blinking (12 Hz) | The port is sending or receiving data. | ||
- | Off | No link is established on the port. |
Silkscreen | Name | Description |
---|---|---|
RST | RST button | To restart the device, press the RST button. Ensure that the running configuration is saved before pressing the RST button. This button enables you to restore the default settings with one click. To be specific, you can press and hold down the RST button for 5 seconds and then release it to restore the default settings and restart the device. |
OFL | OFL button | To remove a hard disk, press and hold the OFL button for 4 seconds until the OFL indicator turns on. |
Ports
1. HDD/SSD slot |
2. Combo port |
3. GE electrical port |
4. 10GE optical port |
5. Console port |
6. MGMT port |
7. USB 3.0 port |
- |
- |
- |
Port | Connector Type | Description | Available Components |
---|---|---|---|
HDD/SSD slot | - | Hard disks are optional and can be purchased from Huawei if necessary. |
NOTE:
In V600R022C00 and later versions, SSD-SATA240G-C and SSD-SATA960G-C hard disks are supported. |
Combo ports (0 to 7) | RJ45+SFP | The combo port is a logical port that consists of an electrical port and an optical port on the panel. The device has only one internal forwarding port. The electrical port and its corresponding optical port are multiplexed. They cannot work at the same time. (For example, when an optical port is activated, the corresponding electrical port is automatically disabled.) Electrical and optical ports share the same interface view and are numbered from GE 0/0/0 to GE 0/0/7. By default, the combo port works as an electrical port. You can run the combo enable fiber command to select an optical port or run the undo combo enable fiber command to select an electrical port based on networking requirements. | |
GE electrical ports (8 to 11) | RJ45 | Four 10/100/1000M autosensing Ethernet electrical ports numbered from GE 0/0/8 to GE 0/0/11. | |
10GE optical ports (0 to 9) | SFP+ | Ten 10GE auto-sensing Ethernet optical ports numbered from 10GE 0/0/0 to 10GE 0/0/9. They can also be used as GE optical ports. | |
Console port | RJ45 | The console port is connected to a console for on-site configuration. You can use a console cable to connect the console port (RJ45) on the device to the COM port on your PC and use the terminal emulation program on the PC to access the command configuration interface of the device to configure, manage, and maintain the device through commands. | |
MGMT port | RJ45 | The out-of-band management port is a 10/100/1000M RJ45 autosensing Ethernet port. The port number is MEth0/0/0 and the default IP address is 192.168.0.1. You can connect this port to the network port or any reachable port on a PC through an Ethernet cable. Then, you can use STelnetv2 to access the CLI of the device or use the web browser to access the web UI to configure, manage, and maintain the device. NOTE:
The MGMT port cannot be used as a service port. |
|
USB 3.0 port | USB 3.0 Type A | USB ports allow you to insert USB devices for system software upgrades. For details about the upgrade through a USB flash drive, see the Upgrade Guide delivered with the version. NOTE:
This interface is supported in V600R021C00 and later versions. |
|
Power Supply System
The power supply system has two PAC600S12-PB AC power modules for 1+1 power redundancy.
Heat Dissipation System
The heat dissipation system consists of four FAN-031A-B modules working in 3+1 backup mode. From the front panel, the device provides a front-to-rear air flow. The fan module locates at the air exhaust of the system.
Technical Specifications
Item | Specification |
---|---|
Installation Type | Rack |
Cabinet installation standard | Cabinet with a depth of 600 mm or above |
Dimensions without packaging (H x W x D) [mm(in.)] |
|
Dimensions with packaging (H x W x D) [mm(in.)] | 185 mm x 550 mm x 650 mm (7.28 in. x 21.65 in. x 25.59 in.) |
Chassis height [U] | 1 U |
Weight with packaging [kg(lb)] | 10.3 kg (22.71 lb) |
Weight without packaging [kg(lb)] | 7.3 kg (16.09 lb) |
CPU | 1 CPU, 16 Cores/CPU, up to 2.0 GHz |
Memory | DDR4 32GB with ECC |
NOR Flash | 64 MB |
NAND Flash | 4 GB |
Hard disk | Optional. You can purchase a 2.5-inch SATA hard disk from Huawei based on the site requirements. The hard disk is hot swappable. For details, see the description of HDD and SDD in Storage Devices > Hard Disk. |
Console port | RJ45 |
Eth Management port | RJ45 |
Typical power consumption [W] | 115.1 W |
Typical heat dissipation [BTU/hour] | 392.7 BTU/hour |
Maximum power consumption [W] | 179.1 W |
Maximum heat dissipation [BTU/hour] | 611.1 BTU/hour |
MTBF [years] | 46.11 years |
MTTR [hours] | 1 hours |
Availability | 0.999998 |
Power supply mode | AC pluggable |
Number of power modules | 2 |
Redundant power supply | 1+1 |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | 8 A/power module |
Rated output power [W] | 600W/12V |
Maximum output power [W] | 600 W/power module |
Types of fans | Pluggable |
Number of fan modules | 4 |
Automatic fan speed adjustment | Supported |
Heat dissipation mode | The fan module locates at the air exhaust of the system. |
Airflow direction | Front-to-back airflow |
Redundant fans | 3+1 |
PoE | Not supported |
Noise at normal temperature (acoustic power) [db(A)] | ≤72dB(A) |
Long-term operating temperature [°C(°F)] |
|
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] |
|
Storage altitude [m(ft.)] | 0 m to 5000 m (0 ft to 16404 ft) |
- The width does not include the size of mounting ears.
- The height is 1U (1U = 1.75 inches, or about 44.45 mm), which is a height unit defined in International Electrotechnical Commission (IEC) 60297 standards.
- Temperature and humidity are measured 1.5 m above the floor and 0.4 m in front of the rack when no protection plate exists before or after the rack.
- The operating temperature change rate of a device with HDDs must be less than or equal to 20°C/hour.