WLAN Hardware Installation and Maintenance Guide

AirEngine 9700-M1 (02354FRN-001)

AirEngine 9700-M1 (02354FRN-001)

Overview

Table 1-61 Basic information about the AirEngine 9700-M1
Item Details
Description AirEngine9700-M1 mainframe (12*GE ports, 12*10GE SFP+ ports, 2*40GE QSFP+ ports, no power)
Part Number 02354FRN-001
Model AirEngine 9700-M1
First supported version V200R021C10SPC600

Depending on the production batch, the device has multiple part numbers, which have the same software specifications but different minimum versions supported. Additionally, the hardware specifications, such as the weight and power consumption, are slightly different.

Appearance

Figure 1-37 Appearance of the AirEngine 9700-M1

Ports

Figure 1-38 Ports on the AirEngine 9700-M1

1

GE

2

SFP+

3

QSFP+

4

USB

5

CON

6

ETH

Table 1-62 Ports on the AirEngine 9700-M1
Port Connector Type Description Available Components
GE RJ45 Twelve 10/100/1000BASE-T Ethernet electrical ports

Network cable

SFP+ SFP+ Twelve 10GE SFP+ Ethernet optical ports, supporting GE/10GE auto-sensing.

GE optical module

10GE optical module

QSFP+ QSFP+

Two 40GE QSFP+ Ethernet optical ports.

QSFP+ port 1 and the SFP+ ports 1 to 4 work as combo ports. By default, QSFP+ port 1 is available, and SFP+ ports 1 to 4 are unavailable. If any of SFP+ ports 1 to 4 is enabled using the set device port-config-mode xge-port enable command, QSFP+ port 1 is unavailable.

40GE optical module

USB USB 3.0 Type A Standard USB 3.0 port. A USB port connects to a USB flash drive to transfer configuration files and upgrade files.

USB storage device

CON RJ45 Console port

Console cable

ETH RJ45 ETH management port that supports 10/100/1000 Mbit/s auto-sensing and full-duplex mode

Network cable

Indicators and Buttons

Figure 1-39 Indicators and buttons on the AirEngine 9700-M1

1

PWR indicator

2

SYS indicator

3

USB indicator

4

CLOUD indicator

5

RST button

6

Service port indicators

7

ETH indicator

8

Fan indicator

9

Power module indicator

-

-

Table 1-63 Indicators on the AirEngine 9700-M1
Silkscreen Name Color Status Description
PWR Power module indicator - Off No power module is installed, or the power module is faulty when a single power module is used.
Green Steady on The power module is properly installed and working properly.
SYS System status indicator - Off The system is not running.
Green Blinking once every 0.25s (4 Hz) The system is starting.
Green Slow blinking (0.5 Hz) The system is running properly.
Green Steady on The system is being powered on or restarted.
Red Steady on
  • The system is faulty.
  • The fan is abnormal.
  • The power supply is abnormal.
NOTE:

When the device supports two system power modules, if only one power module is installed and running properly, the system indicator does not turn on. If two power modules are installed and one or both of them are faulty, the system indicator turns red.

USB USB indicator - Off No USB device is connected.
Green Steady on A USB device is connected and working properly.
CLOUD CLOUD indicator - Off The SDN controller is not connected or the connection is interrupted.
Green Steady on The SDN controller is properly connected.
Green Blinking once every 0.25s (4 Hz) The SDN controller is being connected.
- ETH port indicator - Off The ETH port is not connected.
Green Steady on The ETH port is connected.
Green Blinking The ETH port is transmitting or receiving data.
- GE electrical port indicator - Off No link is established on the port.
Green Steady on The link is established.
Green Blinking Data is being transmitted or received.
- SFP+ optical port indicator - Off No link is established on the port.
Green Steady on The link is established.
Yellow Blinking Data is being transmitted or received.
- QSFP+ indicator - Off No link is established on the port.
Green Steady on The link is established.
Green Blinking Data is being transmitted or received.
- Fan module indicator - Off A fan module is absent.
Green Blinking Fans are working properly.
Red Blinking The fan speed is abnormal or the fan stops rotating.
STAT Power module indicator - Off The power input is abnormal (no input, input overvoltage, or input undervoltage), or the power output is abnormal (undervoltage or overtemperature).
Green Steady on The power module is working properly.
Table 1-64 Buttons on the AirEngine 9700-M1
Silkscreen Name Description
RST Reset button
  • Press this button for less than or equal to 3 seconds to manually reset the device, which interrupts services. Therefore, exercise caution when you perform this operation.
  • Press and hold down this button for more than 5 seconds to restore the factory settings and restart the device.

Heat Dissipation System

The heat dissipation mode of the device is forced air cooling. Air flows in from the front side, and hot air exhausts from the fans at the rear.

Technical Specifications

Table 1-65 Technical specifications of the AirEngine 9700-M1
Item Specification
Installation Type Rack
Dimensions without packaging (H x W x D) [mm(in.)]

Basic: 43.6 mm x 442 mm x 420 mm (1.72 in. x 17.40 in. x 16.54 in.)

Maximum: 43.6 mm x 442 mm x 444 mm (1.72 in. x 17.40 in. x 17.48 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 175 mm x 650 mm x 550 mm (6.89 in. x 25.59 in. x 21.65 in.)
Weight without packaging [kg(lb)] 6.25 kg (13.78 lb)
Weight with packaging [kg(lb)] 8.5 kg (18.74 lb)
Storage M.2 memory card 32 GB
Console port RJ45
Eth Management port RJ45
Maximum power consumption [W] 163.4 W
Maximum heat dissipation [BTU/hour] 557.49 BTU/hour
Power supply mode Pluggable power supply
Number of power modules 2
Service port surge protection 6 kV in common mode
Types of fans Pluggable
Number of fan modules 3
Maximum number of physical ports on the entire device

2*40G (QSFP+)+12*10GE (SFP+)+12*GE

One 40G interface and four 10G interfaces are mutually exclusive.

Long-term operating temperature [°C(°F)] 0°C to 45°C (32°F to 113°F) (From 1800 m to 5000 m [5905.51 ft. to 16404.20 ft.], the maximum ambient temperature decreases by 1°C [1.8°F] for every 300 m [984.25 ft.] increase in altitude.)
Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)
Long-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)] –60 m to +5000 m (–196.85 ft to +16404.20 ft)
Atmospheric pressure [kPa] 53kPa - 106kPa ETSI 300 019-2-3
Noise at normal temperature (acoustic power) [dB(A)] ≤ 55 dBA
Ground Ground
USB Standard USB 3.0 port (host type A) x 1
MTBF [year] 28 year
MTTR [hour] 2 hour