WLAN Hardware Installation and Maintenance Guide
AirEngine 9700-M1 (02354FRN-001)
Overview
Item | Details |
---|---|
Description | AirEngine9700-M1 mainframe (12*GE ports, 12*10GE SFP+ ports, 2*40GE QSFP+ ports, no power) |
Part Number | 02354FRN-001 |
Model | AirEngine 9700-M1 |
First supported version | V200R021C10SPC600 |
Depending on the production batch, the device has multiple part numbers, which have the same software specifications but different minimum versions supported. Additionally, the hardware specifications, such as the weight and power consumption, are slightly different.
Appearance
Ports
1 |
GE |
2 |
SFP+ |
3 |
QSFP+ |
4 |
USB |
5 |
CON |
6 |
ETH |
Port | Connector Type | Description | Available Components |
---|---|---|---|
GE | RJ45 | Twelve 10/100/1000BASE-T Ethernet electrical ports | Network cable |
SFP+ | SFP+ | Twelve 10GE SFP+ Ethernet optical ports, supporting GE/10GE auto-sensing. | GE optical module 10GE optical module |
QSFP+ | QSFP+ | Two 40GE QSFP+ Ethernet optical ports. QSFP+ port 1 and the SFP+ ports 1 to 4 work as combo ports. By default, QSFP+ port 1 is available, and SFP+ ports 1 to 4 are unavailable. If any of SFP+ ports 1 to 4 is enabled using the set device port-config-mode xge-port enable command, QSFP+ port 1 is unavailable. |
40GE optical module |
USB | USB 3.0 Type A | Standard USB 3.0 port. A USB port connects to a USB flash drive to transfer configuration files and upgrade files. | USB storage device |
CON | RJ45 | Console port | Console cable |
ETH | RJ45 | ETH management port that supports 10/100/1000 Mbit/s auto-sensing and full-duplex mode | Network cable |
Indicators and Buttons
1 |
PWR indicator |
2 |
SYS indicator |
3 |
USB indicator |
4 |
CLOUD indicator |
5 |
RST button |
6 |
Service port indicators |
7 |
ETH indicator |
8 |
Fan indicator |
9 |
Power module indicator |
- |
- |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
PWR | Power module indicator | - | Off | No power module is installed, or the power module is faulty when a single power module is used. |
Green | Steady on | The power module is properly installed and working properly. | ||
SYS | System status indicator | - | Off | The system is not running. |
Green | Blinking once every 0.25s (4 Hz) | The system is starting. | ||
Green | Slow blinking (0.5 Hz) | The system is running properly. | ||
Green | Steady on | The system is being powered on or restarted. | ||
Red | Steady on |
NOTE:
When the device supports two system power modules, if only one power module is installed and running properly, the system indicator does not turn on. If two power modules are installed and one or both of them are faulty, the system indicator turns red. |
||
USB | USB indicator | - | Off | No USB device is connected. |
Green | Steady on | A USB device is connected and working properly. | ||
CLOUD | CLOUD indicator | - | Off | The SDN controller is not connected or the connection is interrupted. |
Green | Steady on | The SDN controller is properly connected. | ||
Green | Blinking once every 0.25s (4 Hz) | The SDN controller is being connected. | ||
- | ETH port indicator | - | Off | The ETH port is not connected. |
Green | Steady on | The ETH port is connected. | ||
Green | Blinking | The ETH port is transmitting or receiving data. | ||
- | GE electrical port indicator | - | Off | No link is established on the port. |
Green | Steady on | The link is established. | ||
Green | Blinking | Data is being transmitted or received. | ||
- | SFP+ optical port indicator | - | Off | No link is established on the port. |
Green | Steady on | The link is established. | ||
Yellow | Blinking | Data is being transmitted or received. | ||
- | QSFP+ indicator | - | Off | No link is established on the port. |
Green | Steady on | The link is established. | ||
Green | Blinking | Data is being transmitted or received. | ||
- | Fan module indicator | - | Off | A fan module is absent. |
Green | Blinking | Fans are working properly. | ||
Red | Blinking | The fan speed is abnormal or the fan stops rotating. | ||
STAT | Power module indicator | - | Off | The power input is abnormal (no input, input overvoltage, or input undervoltage), or the power output is abnormal (undervoltage or overtemperature). |
Green | Steady on | The power module is working properly. |
Silkscreen | Name | Description |
---|---|---|
RST | Reset button |
|
Heat Dissipation System
The heat dissipation mode of the device is forced air cooling. Air flows in from the front side, and hot air exhausts from the fans at the rear.
Technical Specifications
Item | Specification |
---|---|
Installation Type | Rack |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic: 43.6 mm x 442 mm x 420 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum: 43.6 mm x 442 mm x 444 mm (1.72 in. x 17.40 in. x 17.48 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 175 mm x 650 mm x 550 mm (6.89 in. x 25.59 in. x 21.65 in.) |
Weight without packaging [kg(lb)] | 6.25 kg (13.78 lb) |
Weight with packaging [kg(lb)] | 8.5 kg (18.74 lb) |
Storage | M.2 memory card 32 GB |
Console port | RJ45 |
Eth Management port | RJ45 |
Maximum power consumption [W] | 163.4 W |
Maximum heat dissipation [BTU/hour] | 557.49 BTU/hour |
Power supply mode | Pluggable power supply |
Number of power modules | 2 |
Service port surge protection | 6 kV in common mode |
Types of fans | Pluggable |
Number of fan modules | 3 |
Maximum number of physical ports on the entire device | 2*40G (QSFP+)+12*10GE (SFP+)+12*GE One 40G interface and four 10G interfaces are mutually exclusive. |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) (From 1800 m to 5000 m [5905.51 ft. to 16404.20 ft.], the maximum ambient temperature decreases by 1°C [1.8°F] for every 300 m [984.25 ft.] increase in altitude.) |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | –60 m to +5000 m (–196.85 ft to +16404.20 ft) |
Atmospheric pressure [kPa] | 53kPa - 106kPa ETSI 300 019-2-3 |
Noise at normal temperature (acoustic power) [dB(A)] | ≤ 55 dBA |
Ground | Ground |
USB | Standard USB 3.0 port (host type A) x 1 |
MTBF [year] | 28 year |
MTTR [hour] | 2 hour |