S5700 Series Switches Hardware Description (V200)

S5731-S32ST4X (98011813)

S5731-S32ST4X (98011813)

Overview

Table 4-1354 Basic information about the S5731-S32ST4X
Item Details
Description S5731-S32ST4X(8*10/100/1000BASE-T ports, 24*GE SFP ports, 4*10GE SFP+ ports, without power module)
Part Number 98011813
Model S5731-S32ST4X
First supported version V200R021C01

Components

Figure 4-533 S5731-S32ST4X appearance

1

Eight 10/100/1000BASE-T ports

2

Twenty-four 100/1000BASE-X ports

NOTE:

In V200R023C00 and later versions, 100/1000BASE-X ports can be configured to work at 2.5 Gbit/s using the port mode 2.5ge command.

3

Four 10GE SFP+ ports

4

One console port

5

One ETH management port

6

One PNP button

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

7

Ground screw

NOTE:
It is used with a ground cable.

8

Power module slot 1

9

Power module slot 2

-

-

Ports

Table 4-1355 Ports on the S5731-S32ST4X
Port Connector Type Description Available Components
10/100/1000BASE-T port RJ45 A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s.

Ethernet cable

100/1000BASE-X port SFP

A 100/1000BASE-X port can send and receive data at 100 Mbit/s, 1000 Mbit/s, or 2.5 Gbit/s.

In V200R023C00 and later versions, 100/1000BASE-X ports can be configured to work at 2.5 Gbit/s using the port mode 2.5ge command.

10GE SFP+ optical port SFP+ A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s.
Console port RJ45 The console port is connected to a console for on-site configuration.

Console cable

ETH management port RJ45

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely.

You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port.

Ethernet cable

Indicators and Buttons

Figure 4-534 Indicators on the S5731-S32ST4X
Table 4-1356 Description of indicators on the switch

No.

Indicator

Name

Color

Status

Description

1

PWR1

Power module indicator

-

Off

No power module is available in power module slot 1, or the switch has only one power module but the power module does not work normally.

Green

Steady on

A power module is installed in power module slot 1 and is working normally.

Yellow

Steady on

The switch has two power modules installed. Any of the following situations occurs in power module slot 1:

  • A power module is available in this slot but it is not connected to a power source.

  • The power module in this slot has failed.

2

PWR2

Power module indicator

-

Off

No power module is available in power module slot 2, or the switch has only one power module but the power module does not work normally.

Green

Steady on

A power module is installed in power module slot 2 and is working normally.

Yellow

Steady on

The switch has two power modules installed. Any of the following situations occurs in power module slot 2:

  • A power module is available in this slot but it is not connected to a power source.

  • The power module in this slot has failed.

3

SYS

System status indicator

-

Off

The system is not running.

Green

Fast blinking

The system is starting.

Green

Steady on

During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds.

Green

Slow blinking

The system is running normally.

Red

Steady on

The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated.

4

MST

Stack indicator

-

Off

The switch is not the master switch in a stack.

Green

Blinking

The switch is the master switch in a stack or a standalone switch.

5

ID

ID indicator

-

Off

The ID indicator is not used (default state).

Blue

Steady on

The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain.

6

-

Service port indicator (electrical port)

The indicator in the upper left corner of a port indicates the indicator of a port at the top, and the indicator in the upper right corner indicates the indicator of a port at the bottom.

-

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

Blinking

The port is sending or receiving data.

7

-

Service port indicator (optical port)

Each optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green).

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

NOTE:

If a power failure occurs on a device's PCB board, indicators of the last four optical ports on the device's front panel blink green cyclically at an interval of 1 second, with each indicator illuminating for 0.25 seconds.

Green

Off

The port is not connected or has been shut down.

Steady on

A link has been established on the port.

Yellow

Off

The port is not sending or receiving data.

Blinking

The port is sending or receiving data.

8

L/A

ETH port indicator

-

Off

The ETH port is not connected.

Green

Steady on

The ETH port is connected.

Green

Blinking

The Eth port is sending or receiving data.

Power Supply System

The switch can use a single power module or two power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch. However, the power modules with fans and power modules without fans cannot be installed on the same switch.

Heat Dissipation System

The switch has three built-in fans for forced air cooling. Air flows in from the left, right, and front sides, and exhausts from the rear panel.

This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 4-1357 Technical specifications of the S5731-S32ST4X
Item Specification
Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. x 17.40 in. x 17.64 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.)
Chassis height [U] 1 U
Chassis material Metal
Weight without packaging [kg(lb)] 4.9 kg (10.80 lb)
Weight with packaging [kg(lb)] 7.43 kg (16.38 lb)
Typical power consumption [W] 73.56 W
Typical heat dissipation [BTU/hour] 250.99 BTU/hour
Maximum power consumption [W]

104.82 W (150 W AC or 180 W DC)

119.23 W (600 W AC)

Maximum heat dissipation [BTU/hour]

357.66 (150 W AC or 180 W DC)

406.82 (600 W AC)

Static power consumption [W] 44.5 W
MTBF [years] 71.54 years
Availability > 0.99999
Noise at normal temperature (acoustic power) [dB(A)] 45.47 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)] 31.79 dB(A)
Number of card slots 0
Number of power slots 2
Number of fans modules 3
Redundant power supply

1+1

Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together.

Long-term operating temperature [°C(°F)] -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Short-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)]

When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:

  • The operating temperature exceeds 45°C (113°F) for a maximum of 96 consecutive hours in a year.
  • The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours.
  • The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year.

If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur.

Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km.

Storage temperature [°C(°F)] -40°C to +70°C (-40°F to +158°F)
Long-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Power supply mode Pluggable power supply
Rated input voltage [V]
  • AC input: 100 V AC to 240 V AC, 50/60 Hz
  • High-voltage DC input: 240 V DC
  • DC input: –48 V DC to –60 V DC
Input voltage range [V]
  • AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz
  • High-voltage DC input: 190 V DC to 290 V DC
  • DC input: –38.4 V DC to –72 V DC
Maximum input current [A] The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.
Memory 2 GB
Flash memory The physical space is 1 GB. You can run the display version command to view the actual available space.
Console port RJ45
Eth Management port RJ45
USB Not supported
RTC Supported
RPS input Not supported
Service port surge protection [kV] Common mode: ±7 kV
Power supply surge protection [kV]
  • Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode
  • Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
Ingress protection level (dustproof/waterproof) IP20
Types of fans Built-in
Heat dissipation mode Heat dissipation with fan, intelligent fan speed adjustment
Airflow direction Air intake from left,front and right, air exhaustion from behind
PoE Not supported
Certification

EMC certification

Safety certification

Manufacturing certification

Translation
Favorite
Download
Update Date:2025-04-03
Document ID:EDOC1000013597
Views:7463029
Downloads:62647
Average rating:3.07Points

Digital Signature File