CloudEngine S5700 Series Switches Hardware Description (V600)

S5735-L8T4S-A-V2

S5735-L8T4S-A-V2

Overview

Table 4-197 Basic information about the S5735-L8T4S-A-V2
Item Details
Description S5735-L8T4S-A-V2 (8*10/100/1000BASE-T ports, 4*GE SFP ports, AC power)
Part Number 98011977
Model S5735-L8T4S-A-V2
First supported version V600R022C01

Components

Figure 4-77 S5735-L8T4S-A-V2 appearance

1

One MODE button

2

Eight 10/100/1000BASE-T ports

3

Four 1000BASE-X ports

4

One console port

5

One PNP button

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

6

Ground screw

NOTE:
It is used with a ground cable.

7

AC socket

NOTE:

It is used with an AC power cable.

8

Jack for AC power cable locking strap

NOTE:
The AC power cable locking strap is not delivered with the switch.

Ports

Table 4-198 Ports on the S5735-L8T4S-A-V2
Port Connector Type Description Available Components
10/100/1000BASE-T port RJ45 A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s.

Ethernet cable

1000BASE-X port SFP A 1000BASE-X port can send and receive data at 1000 Mbit/s.
Console port RJ45 The console port is connected to a console for on-site configuration.

Console cable

Indicators and Buttons

The S5735-L8T4S-A-V2 has similar indicators to those on the S5735-L8P2T4X-A-V2 except that the S5735-L8T4S-A-V2 does not have a PoE mode indicator. For details, see the S5735-L8P2T4X-A-V2.

Power Supply System

The switch has a built-in AC power module and does not support pluggable power modules.

Heat Dissipation System

The switch has a built-in fan for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.

When working properly at a normal temperature, the device meets the desktop-class noise requirements. However, the fan speed may be high and the noise may be loud during device startup.

This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 4-199 Technical specifications of the S5735-L8T4S-A-V2
Item Specification
Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 250.0 mm x 180.0 mm (1.72 in. x 9.84 in. x 7.09 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 250.0 mm x 187.0 mm (1.72 in. x 9.84 in. x 7.36 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 90.0 mm x 370.0 mm x 380.0 mm (3.54 in. x 14.57 in. x 14.96 in.)
Chassis height [U] 1 U
Chassis material Metal
Weight without packaging [kg(lb)] 1.41 kg (3.11 lb)
Weight with packaging [kg(lb)] 2.22 kg (4.89 lb)
Typical power consumption [W] 15.95 W
Typical heat dissipation [BTU/hour] 54.42 BTU/hour
Maximum power consumption [W] 21.52 W
Maximum heat dissipation [BTU/hour] 73.43 BTU/hour
Static power consumption [W] 10.52 W
MTBF [years] 75.32 years
Availability > 0.99999
Noise at normal temperature (acoustic power) [dB(A)] 44.5 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)] 32.5 dB(A)
Number of card slots 0
Number of power slots 0
Number of fans modules 1
Redundant power supply Not supported
Long-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
Restriction on the operating temperature variation rate [°C(°F)]

When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Devices cannot start when the temperature is lower than 0°C (32°F).

Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)
Long-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)] 0–5000 m (0–16404 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Power supply mode AC built-in
Rated input voltage [V] AC input: 100–240 V AC; 50/60 Hz
Input voltage range [V] AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz
Maximum input current [A] 0.8 A
Memory 2 GB
Flash memory Physical space: 1 GB
Console port RJ45
Eth Management port Not supported
USB Not supported
RTC Not supported
RPS input Not supported
Service port surge protection [kV] Common mode: ±7 kV
Power supply surge protection [kV] Differential mode: ±6 kV; common mode: ±6 kV
Ingress protection level (dustproof/waterproof) IP20
Types of fans Built-in
Heat dissipation mode Air cooling for heat dissipation, intelligent fan speed adjustment
Airflow direction Air intake from left and front, air exhaustion from right
PoE Not supported
Certification

EMC certification

Safety certification

Manufacturing certification