2009 String Short-Circuited to Ground

2009 String Short-Circuited to Ground

Alarm Attribute

Alarm ID

Alarm Name

Alarm Severity

2009

String Short-Circuited to Ground

Major

Possible Cause

Cause ID

Possible Cause

1

  1. A short circuit has occurred between the PV array and the ground.
  2. The ambient air of the PV array is damp and the insulation between the PV array and the ground is poor.

Suggestion

  1. Check the output-to-ground impedance of the PV array. If a short circuit or inadequate insulation is detected, rectify it.
  2. If auto recovery from string-to-ground short-circuit protection is disabled, check and rectify the preceding faults, and manually clear the alarm.
  3. If auto recovery from string-to-ground short-circuit protection is enabled, the alarm will be automatically cleared after fault recovery.