CloudEngine 16800, 12800, 9800, 8800, 7800, 6800, and 5800 Series Switches Troubleshooting Guide (V100 and V200)
How Do I Handle an MPU's Failure to Obtain the System Software Package During a Startup?
If an MPU of a switch restarts repeatedly and the console display shows the following information, the MPU fails to obtain the system software package.
*************************************************************
* Copyright (C) <2012-2013> Huawei Technologies Co., Ltd. *
*************************************************************
CloudEngine BIOS Version: 221 (Oct 24 2013 - 16:37:30)
Board Name ..................................... CE-MPUA
SDRAM Memory Initializing ...................... BEGIN
SDRAM Memory Size .............................. 8 Gbytes
SDRAM Memory Initializing ...................... DONE
Press CTRL+T for full memory test .............. skip
Starting ...
Press CTRL+B to enter BIOS menu or CTRL+E to boot DFX: 0
The startup file is NULL, please set the correct startup file.
Auto boot fail ...
If this fault occurs, perform the following steps to locate the fault (save operation records):
Take system software package CE12800-V100R002C00SPC200.cc as an example. The operation procedure is as follows:
Press CTRL+B to enter BIOS menu: //Press CTRL+B to enter the BIOS menu. Password: //Enter the BIOS password. BIOS Menu (Version: 221) 1. Continue to boot 2. Update from serial interface 3. Update from ethernet interface 4. Modify startup parameters 5. File system 6. Modify BIOS password 7. Modify console password //This option is not supported in V200R019C00 and later versions. 8. Reboot Enter your choice(1-8): 5 File system Submenu 1. List flash files 2. Upload file to server 3. Return Enter your choice(1-3): 1 ... 71803089 Sun Jan 23 08:58:44 2000 CE12800-V100R002C00SPC200.cc
In the file system submenu, select 3. Return to return to the BIOS menu.
- Check the current startup file. The operation procedure is as follows:
BIOS Menu (Version: 221) 1. Continue to boot 2. Update from serial interface 3. Update from ethernet interface 4. Modify startup parameters 5. File system 6. Modify BIOS password 7. Modify console password 8. Reboot Enter your choice(1-8): 4 Startup Submenu 1. Display current startup configuration 2. Modify startup configuration 3. Return Enter your choice(1-3): 1 Current boot disk : flash Current startup file : <NULL> Current config file : <NULL>
- Modify system startup parameters. The operation procedure is as follows:
Startup Submenu 1. Display current startup configuration 2. Modify startup configuration 3. Return Enter your choice(1-3): 2 '.' = clear field; Ctrl+C = quit; Enter = use current configuration Current startup file is "<NULL>", modify the file name if needed. Input the new file name: CE12800-V100R002C00SPC200.cc //Specify the next startup file. The startup file has been modified from "<NULL>" to "CE12800-V100R002C00SPC200.cc". Current config file is "<NULL>", modify the file name if needed. Input the new file name: //Retain the original configuration file and press Enter to return to the startup submenu. Startup Submenu 1. Display current startup configuration 2. Modify startup configuration 3. Return Enter your choice(1-3): 1 //Check whether the startup file is successfully changed. Current boot disk : flash Current startup file : CE12800-V100R002C00SPC200.cc Current config file : <NULL>
Select 3. Return to return to the BIOS menu.
Step 3: In the BIOS menu, select 8. Reboot to restart the switch and observe the BIOS display to check whether the switch can start normally. If not, go to step 4.
Step 4: If the flash memory does not contain the system software package, or the MPU still fails to restart after the path is reconfigured, reload the system software package. The operation procedure is as follows:
Log in to Huawei enterprise technical support website to download the system software package of the corresponding version and load it on the switch. After loading the system software package, check whether the switch starts normally.
Collect operation records on the serial interface or network interface, and save the records in a text file.
Collect user logs and diagnostic logs. For details, see How Do I Collect Logs of a Device?.
Observe the blue E-USB storage indicator in the inner left side of the MPU panel. The indicator can be steady on, blink fast, blink slowly, or be off.
After collecting the preceding information, connect the serial cable to another MPU. The switch restarts normally. After entering the command line interface, run the power { off | on } slot slot-id command in the user view or system view to power off and then power on the faulty MPU and check whether the switch starts normally.
To prevent information loss, power off the MPU after collecting the preceding information.